No Integration
The defining characteristics of a No Integration
installation include:
• No integration of the Pro Xpc Auto Air Spray Gun
or Controller.
• Local operation using the Pro Xpc Auto Controller
interface.
• Interlocks managed independently of the spray
gun installation.
To reduce the risk of fire and explosion, the
controller (B) must be electrically interlocked with
the spray booth ventilation fans to prevent the gun
from operating without ventilation fans operating.
Non-Hazardous Location
Hazardous Location
KEY:
A
Pro Xpc Auto Air Spray
Gun
B
Pro Xpc Auto Controller
C
Gun Power Cable
D
Fluid Supply
F
‡
Fluid Hose Ground
Bracket
G
‡
Fluid Bracket Ground
Wire
H
‡
Fluid Supply Tube
(Graco-supplied) to gun
fluid inlet, maximum 8 ft
(2.4 m) length
†
Graco Waterborne Fluid
Supply Hose, from L to
gun inlet (hose must be
a single, uninterrupted
length).
J
‡
Fluid Supply Hose
K
Pro Xpc Auto Controller
Ground Wire
L
Fluid Regulator
M
†
Isolation Enclosure
X
Controller Power Cord
†
Waterborne systems only
‡
Solventborne systems only
Typical Installation With No Integration
333266D
9