Setup Screen 4
Use Setup Screen 4 (Parameter P04) to select the
output signal type for the discrete I/O interface analog
outputs (Ao). Press buttons T5/T6 to change the
setting. The options are:
• 0 = VoLt: Analog outputs are voltage type (0-10V).
This selection is the default.
• 1 = CUrr: Analog outputs are current type
(4-20mA).
This setting applies to Actual Spraying Current and
Actual Spraying Voltage analog outputs for the
discrete I/O interface. See
, for
more information.
Setup Screen 5
Setup Screen 5 (Parameter P05) is not used.
Setup Screen 6
Setup Screen 6 (Parameter P06) is not used.
Setup Screen 7
Use Setup Screen 7 (Parameter P07) to select the
log level (LoG) for how much information is logged in
the system (used for troubleshooting only). Press
buttons T5/T6 to change the setting. A setting of
0 means nothing is logged. A setting of 5 means
everything is logged. 2 is the default.
NOTE: For logging, a micro SD card must be inserted
in the slot found on the main circuit board. If a
software update has been done by installing a micro
SD card, this card can be used for logging. If no
card has been installed, or to verify whether one is
present, see
.
The controller can export log reports of controller
activity to an installed micro SD card for test purposes
and for finding defects.
NOTE: If a micro SD card is present when the
controller is turned on, the log messages are
recorded in a file (MESSAGES.LOG) located in
the root directory. When the file size reaches
32 MB, it is renamed MESSAGES.1 and a new
MESSAGES.LOG file is created. Subsequent log file
names will be sequentially numbered.