background image

All written and visual data contained in this document reflects the latest product information available at the time of publication. 

Graco reserves the right to make changes at any time without notice.

Original instructions.

 This manual contains English. MM 3A3383

Graco Headquarters: 

Minneapolis

International Offices: 

Belgium, China, Japan, Korea

GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA

Copyright 2015, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com

Revision D, June 2018

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in 
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty 
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by 
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written 
recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty 
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of 
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with 
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or 
maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of 
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned 
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will 
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED 
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy 
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or 
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT 
MANUFACTURED BY GRACO

. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to 

the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these 
warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or 
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the 
negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, 
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la 
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite 
de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

For the latest information about Graco products, visi

www.graco.com

.

For patent information, see 

www.graco.com/patents

.

TO PLACE AN ORDER, 

contact your Graco distributor or call to identify the nearest distributor.

Phone: 

612-623-6921

 or Toll Free: 

1-800-328-0211

 Fax: 

612-378-3505

Summary of Contents for President Series

Page 1: ...for flushing or purging lines with caustics acids abrasive line strippers and other similar fluids For professional use only See page 3 for model information including maximum working pressure Important Safety Instructions Read all warnings and instructions in this manual Save these instructions President Pump with Open 4 Ball Lower President Pump with Sealed 4 Ball Lower ...

Page 2: ...ix Tank Volume 11 Stall Test 11 Changing the TSL On Wet Cup Models 11 Troubleshooting 12 Repair 13 Disassembly 13 Reassembly 13 Parts 15 Dimensions 17 Mounting Hole Layouts 18 255143 Wall Bracket Accessory 18 Model 253692 Floor Stand Accessory 19 Performance Charts 20 Technical Data 21 Graco Standard Warranty 22 Graco Information 22 Related Manuals Part No Description 306982 President Air Motor ma...

Page 3: ...1 2 12 17E223 A 2 1 standard 1000cc sst Open npt 460 3 2 32 0 180 1 2 12 17E224 A 2 1 standard 1000cc cs Open npt 460 3 2 32 0 180 1 2 12 17E225 A 3 1 standard 750cc sst Sealed tri clamp 460 3 2 32 0 150 1 0 10 17E226 A 3 1 standard 750cc sst Open npt 460 3 2 32 0 150 1 0 10 17E227 A 3 1 standard 750cc cs Open npt 460 3 2 32 0 150 1 0 10 17E228 A 3 1 stubby 750cc sst Open npt 460 3 2 32 0 150 1 0 ...

Page 4: ...tential static sparking Ground all equipment in the work area See Grounding instructions Never spray or flush solvent at high pressure Keep work area free of debris including solvent rags and gasoline Do not plug or unplug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggering into pail...

Page 5: ...harp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work area Comply with all applicable safety regulations MOVING PARTS HAZARD Moving parts can pinch cut or amputate fingers and other body parts Keep clear of moving parts Do not operate equipment with protective guards or covers removed Pressurized equipment ca...

Page 6: ...rge tank use a ground wire and clamp Dispense valve ground through a connection to a properly grounded fluid hose and pump Fluid supply container follow local code Object being sprayed follow local code Solvent pails used when flushing follow local code Use only conductive metal pails placed on a grounded surface Do not place the pail on a non conductive sur face such as paper or cardboard which i...

Page 7: ...ght ensuring that there is sufficient clearance for the fluid connection line and for servicing the lower 4 Drill four 7 16 in 11 mm holes using the bracket as a template Use either of the two mounting hole groupings in the bracket See Mounting Hole Lay outs page 18 5 Bolt the bracket securely to the wall using bolts and washers designed to hold in the wall s construction 6 Attach the pump assembl...

Page 8: ...rticles from the fluid as it leaves the pump Fluid drain valve N required in your system to relieve fluid pressure in the hose and gun Fluid shutoff valve D shuts off fluid flow Trapped air can cause the pump to cycle unexpect edly which could result in serious injury from splash ing or moving parts Be sure the valve is easily accessible from the pump and located downstream from the air regulator ...

Page 9: ...iameter D Fluid Shutoff Valve E Fluid Line F Surge Tank Stand G Surge Tank H Air Shutoff Valve bleed type J Air Supply Line K Air Line Filter L Air Regulator and Gauge M Bleed Type Master Air Valve N Fluid Drain Valve P Air Line Drain Valve Y Pump Ground Wire required see page 6 for installation FIG 2 Typical Installation A B F G D H M K L N D C E P J Y J N D ...

Page 10: ...ed type air valve M Slowly turn pump air regulator L clockwise increasing pressure until pump starts 8 Cycle pump slowly until all air is pushed out and pump and hoses are fully primed 9 Close the fluid shutoff valve D downstream of the pump The pump should stall against pressure NOTE In a circulation system the pump operates con tinuously until the power supply is shut off In a direct supply syst...

Page 11: ...pump to run too fast which can seriously damage the pump Stall Test Perform a stall test periodically to ensure the piston seal is in good working condition and prevent system pres surization Close the fluid shutoff valve D closest to the pump on the down stroke and be sure that the pump stalls Open the fluid shutoff valve to restart the pump Close the fluid shutoff valve D closest to the pump on ...

Page 12: ...n packings Replace See lower manual No output Improperly installed ball check valves Check and repair Pump operates erratically Exhausted fluid supply Refill and reprime pump Held open or worn ball check valves Check and repair Worn piston packing Replace See lower manual Pump will not operate Restricted air supply lines Clear any obstructions be sure all shut off valves are open increase pressure...

Page 13: ...p to step 2 If the coupling adapter 8 and tie rods 4 have been disassembled from the adapter plate 3 fol low these steps a Screw the tie rods 4 into the adapter plate 3 and torque to 50 55 ft lb 68 75 N m See FIG 5 b Fill the cavity in the bottom of the motor shaft with grease Lubricate the threads of the cou pling adapter 8 Screw the adapter 8 into the motor shaft until the pin holes align and in...

Page 14: ...ith Sealed 4 Ball Lowers Install the shields 9 by engaging the bottom lips with the groove in the top plate Snap the two shields together 9 Flush and test the pump before reinstalling it in the system Connect hoses and flush the pump While it is pressurized check for smooth operation and leaks Adjust or repair as necessary before reinstall ing in the system 10 Reconnect the pump ground wire before...

Page 15: ... 2 LOWER 4 Ball see manual 333022A 1 17K657 Used on model 17E222 17K656 Used on Model 17E225 3 186071 PLATE adapter 1 4 17C261 TIE ROD 8 49 in 215 7 mm 6 21 in 157 8 mm between shoulders 3 5 108683 NUT lock hex 9 16 12 unc 3 6 101946 PIN cotter stainless steel 1 8 16H375 ADAPTER coupling 1 9 24A640 SHIELD KIT includes 2 shields 1 10 17F000 NUT coupling 1 11 184128 COLLAR coupling 2 12 100214 WASHE...

Page 16: ...306982 1 002 LOWER 4 Ball see manual 333022A 1 17K669 Used on model 17E223 17K661 Used on model 17E224 17K668 Used on model 17E226 17K660 Used on model 17E227 17K668 Used on model 17E228 17K660 Used on model 17E229 003 186071 PLATE adapter 1 004 15G924 TIE ROD 16 55 in 420 mm 14 25 in 362 mm between shoulders 3 16H434 TIE ROD 8 37 in 210 mm 10 8 in 274 mm between shoulders Used on Models 17E228 an...

Page 17: ...kg 17E222 1000cc Sealed Standard 49 1244 32 813 25 635 11 5 292 102 46 17E225 750cc Sealed Standard 101 45 17E228 750cc Open Stubby 40 1016 21 533 14 355 71 32 17E229 750cc Open Stubby 17E223 1000cc Open Standard 46 1168 29 736 14 355 74 34 17E224 1000cc Open Standard 17E226 750cc Open Standard 73 33 17E227 750cc Open Standard ...

Page 18: ...451 mm B 14 5 in 368 mm C 12 4 in 314 mm D 9 0 in 229 mm E 5 4 in 137 mm F 7 4 in 187 mm G 5 3 in 133 mm H 2 0 in 51 mm J 1 0 in 25 mm K 1 6 in 41 mm L 2 7 in 69 mm M 4 4 in 112 mm N Four 0 562 in 14 mm diameter holes for mounting to stand P Four 0 438 in 11 mm diameter holes for mounting to wall ...

Page 19: ...Mounting Hole Layouts 3A3383D 19 Model 253692 Floor Stand Accessory 16 88 in 428 8 mm 14 50 in 368 3 mm 17 0 in 431 8 mm 19 88 in 505 0 mm TI15859a ...

Page 20: ...air pressure Test Fluid No 10 Weight Oil 3 1 President with 750cc Lower 500 3 5 35 A B A B C Fluid Pressure psi MPa bar 300 2 0 20 200 1 3 13 100 0 69 6 9 Air Consumption 40 1 12 C 0 30 0 84 20 0 56 10 0 28 scfm m3 min 50 1 40 2 0 7 5 6 0 22 7 10 0 37 8 14 0 53 0 4 0 15 1 8 0 30 2 12 0 45 4 Fluid Flow in gpm lpm 0 2 0 7 5 6 0 22 7 10 0 37 8 14 0 53 0 4 0 15 1 8 0 30 2 12 0 45 4 Fluid Flow in gpm l...

Page 21: ...ow at 60 cycles per minute gpm lpm 17E222 17E223 17E224 14 1 gpm 53 5 lpm 17E225 17E226 17E227 17E228 17E229 9 6 gpm 36 4 lpm Output per Cycle gal cc 17E222 17E223 17E224 0 23 gal 890cc 17E225 17E226 17E227 17E228 17E229 0 16 gal 610cc Maximum Fluid Temperature Rating 150 F 66 C Sound Pressure Levels Input Air Pressures at 15 cycles per minute measured at 1 meter from unit President Air Motor at 4...

Page 22: ...material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warran...

Reviews: