308–333

Table of Contents

Warnings

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Installation

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Operation

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Parts

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Technical Data

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Graco Warranty

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Graco Phone Number

12

. . . . . . . . . . . . . . . . . . . . . . . . . . 

Symbols

Warning Symbol

WARNING

This symbol alerts you to the possibility of serious
injury or death if you do not follow the instructions.

Caution Symbol

CAUTION

This symbol alerts you to the possibility of damage to
or destruction of equipment if you do not follow the
corresponding instructions.

WARNING

INJECTION HAZARD

Spray from the gun, hose leaks, or ruptured components can inject fluid into your body and cause an
extremely serious injury, including the need for amputation. Splashing fluid in the eyes or on the skin
can also cause a serious injury.

Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate medi-
cal attention.

Do not point the spray gun at anyone or at any part of the body.

Do not put hand or fingers over the spray tip.

Do not stop or deflect fluid leaks with your hand, body, glove, or rag.

Do not “blow back” fluid; this is not an air spray system.

Always have the tip guard and the trigger guard on the spray gun when spraying.

Check the gun diffuser operation weekly. Refer to the gun manual.

Be sure the gun trigger safety operates before spraying.

Lock the gun trigger safety when you stop spraying.

Follow the Pressure Relief Procedure on page 7 whenever you: are instructed to relieve pres-
sure; stop spraying; clean, check, or service the equipment; and install or clean the spray tip.

Tighten all the fluid connections before operating the equipment.

Check the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately.
Permanently coupled hoses cannot be repaired; replace the entire hose.

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin,
inhaled, or swallowed.

Know the specific hazards of the fluid you are using.

Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local,
state and national guidelines.

Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and
solvent manufacturer.

Summary of Contents for President 236-066

Page 1: ...formation READ AND KEEP FOR REFERENCE 30 1 RATIO STAINLESS STEEL President Sprayer 3600 psi 25 0 MPa 250 bar Maximum Fluid Working Pressure 120 psi 0 83 MPa 8 3 bar Maximum Air Inlet Pressure Part No 236 066 Wall Mount Pump GRACO INC P O BOX 1441 MINNEAPOLIS MN 55440 1441 http www graco com COPYRIGHT 1993 GRACO INC Graco Inc is registered to I S EN ISO 9001 ...

Page 2: ...y glove or rag Do not blow back fluid this is not an air spray system Always have the tip guard and the trigger guard on the spray gun when spraying Check the gun diffuser operation weekly Refer to the gun manual Be sure the gun trigger safety operates before spraying Lock the gun trigger safety when you stop spraying Follow the Pressure Relief Procedure on page 7 whenever you are instructed to re...

Page 3: ... instruction manuals tags and labels before operating the equipment Use the equipment only for its intended purpose If you are uncertain about usage call your Graco distributor Do not alter or modify this equipment Use only genuine Graco parts and accessories Check the equipment daily Repair or replace worn or damaged parts immediately Do not exceed the maximum working pressure of the lowest rated...

Page 4: ... fluid hoses Air compressor follow manufacturer s recommen dations Spray gun grounding is obtained through connec tion to a properly grounded fluid hose and pump Fluid supply container according to your local code Object being sprayed according to your local code All solvent pails used when flushing according to local code Use only metal pails which are conduc tive placed on a grounded surface Do ...

Page 5: ...r E in the main air line to re move harmful dirt and moisture from the compressed air supply To provide automatic lubrication of the air motor install an air line lubricator P downstream from the pump air regulator F Install a second master air valve D in the main air line to isolate the accessories for servicing Mounting the Pump Mount the wall bracket 5 ft 1 5 m above the floor Be sure the wall ...

Page 6: ...uid Filter Gun Fluid Supply Hose Gun Air Supply Hose Air Assisted Airless Spray Gun Air Line Lubricator Runaway Valve Location for wall mount pumps Fluid Intake Elbow Ground Wire required see page 4 for installation instructions Typical Installation Cart Mount Model Shown NOTE Some components shown are included with the sprayers depend ing on the model Refer to the parts list on page 10 for parts ...

Page 7: ...risk of fluid injection static sparking and splashing in the eyes or on the skin Starting and Adjusting the Pump WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Pressure Relief Procedure on page 7 See Fig 3 Be sure the air regulators 10a and 10b and bleed type master air valve 16 are closed Do not install the spray tip yet Screw the bu...

Page 8: ...r from the fluid sys tem or flush the pump as described in Shutdown and Care at right Shutdown and Care WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Pressure Relief Procedure on page 7 Always relieve the pressure whenever you shut off the pump Stop the pump at the bottom of its stroke to keep fluid from drying on the exposed displac...

Page 9: ...9 308 333 Notes ...

Page 10: ...6 Wall Mount Pump 1 2 02818A 9 39 13 REF 2 2 26 32 7 2 2 5 6 2 25 1 23 A 1 A 13 22 20 2 2 21 34 33 16 15 14 2 2 18 19 2 2 1 35 12 2 8 9 2 10 11 2 28 See Detail Apply thread sealant to male threads except at swivel connections DETAIL ...

Page 11: ... 18 166 999 ELBOW street reducing 1 2 npt n x 1 4 npt f 1 19 162 453 NIPPLE 1 4 npt x 1 4 npsm 1 20 236 076 HOSE suction fluid nylon 3 4 npt mbe 3 4 19 mm ID 6 ft 1 82 m long 1 21 188 867 TUBE suction 3 4 npt m x f stainless steel 1 22 112 192 ELBOW fluid intake 3 4 npt fbe stainless steel 1 23 188 595 BRACKET pump mounting 1 25 100 016 LOCKWASHER spring 1 4 2 26 100 270 CAPSCREW hex hd 1 4 20 x 5...

Page 12: ...tal or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two 2 years of the date of sale GRACO MAKES NO WARRANTY AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN CONNECTION WITH ACCESSORIES EQUIPMENT MA...

Reviews: