DataTrak Operation
311238ZAM
11
DataTrak Operation
Setup Mode
1. See F
IG
. 3. Press and hold
for 5 seconds until
Setup menu appears.
2. To enter settings for runaway, lower size, and flow
rate units, and to enable runaway, E1, E2, and E5
error options, press
to change the value, then
to save the value and move the cursor to the
next data field.
3. Move the cursor to the E5 error enable option field,
then press
once more to exit Setup mode.
Run Mode
Runaway
1. See F
IG
. 3. If pump runaway occurs, the runaway
solenoid will actuate, stopping the pump. The LED
(W) will flash and the display (Y) will indicate a run-
away condition (see Table 1).
2. To reset runaway monitor, close master air valve
(B). Wait for air to completely bleed off the air motor
before going to step 3. The screen will change to
indicate this, as shown below.
3. Press
to clear the diagnostic code and reset
the runaway solenoid.
4. Open master air valve (B) to restart pump.
DataTrak is included with certain models. See page
3 for a list of models featuring DataTrak.
For remote DataTrak models, see your system
operation manuals. See pages 38-39 for parts.
The DataTrak display (Y) will turn off after 1 minute
to save battery life. Press any key to wake up the
display.
When runaway, E1, E2, and E5 error options are
enabled, a
will appear on the setup screen. See
F
IG
. 3.
The runaway control should be tested regularly. To
test, go to Setup Mode and set value to 1 (one).
Pump should stop in six cycles.
To disable runaway monitoring, go to setup mode
and set runaway value to 0 (zero) or toggle (RT) off
(see F
IG
. 3).
B