Operation
10
332245G
Operation
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
1.
Engage the trigger lock.
2.
See F
IG
. 1. Turn off the bleed-type master air valve
(C).
3.
Disengage the trigger lock.
4.
Hold a metal part of the gun firmly to a grounded
metal waste container. Trigger the gun to relieve
fluid pressure.
5.
Engage the trigger lock.
6.
Open all fluid drain valves in the system, having a
waste container ready to catch the drainage. After
the fluid is drained, close the valves.
7.
If you suspect the spray tip or hose is completely
clogged, or that pressure has not been fully relieved
after following the previous steps, very slowly
loosen the tip guard retaining nut or hose end cou-
pling and relieve pressure gradually; then loosen
completely. With tip removed, trigger gun into
bucket.
Trigger Lock
See F
IG
. 5. Always engage gun trigger lock when you
stop spraying to prevent gun from being triggered acci-
dentally by hand or if dropped or bumped.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury
from pressurized fluid, such as skin injection,
splashing fluid and moving parts, follow the Pressure
Relief Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.
F
IG
. 5. Trigger Lock
TI5049a
TI5048a
Gun Trigger
Safety Locked
Gun Trigger
Safety Unlocked