Installation
3A0732P
9
Setup
1.
See F
. 2. Attach one end of fluid hose (K) to pump
outlet (or optional inline fluid filter outlet).
2.
Attach other end of fluid hose to gun fluid inlet at
base of gun (H).
3.
Attach one end of the air hose (G) to gun air regula-
tor (E).
4.
Attach remaining end of the air hose to air inlet at
base of gun (H).
5.
Clip fluid and air hoses together with the supplied
hose clips (qty. of 7). Space clips as needed.
6.
Attach the fluid suction kit (J) to the pump inlet.
F
IG
. 2. Typical Installation (Air-Assisted Stand Mount Package Shown)
A
B
C
D
F
E
G
N
J
K
L
ti15591a
H
M
P
Key:
A
Main Air Supply
Line
B
Air Shutoff Valve
C
Air Filter
D
Bleed-type
Master Air Valve
(required)
E
Gun Air Pressure
Regulator
F
Pump Air
Pressure
Regulator
G
Gun Air Supply
Line
Summary of Contents for MERKUR ES 24F150