background image

Advanced Troubleshooting

309477F

11

Advanced Troubleshooting

WARNING

Page 4.

General Problem: Motor Does Not Operate

Specific Problem

Cause

Solution

Power switch is on and sprayer 
is plugged in; pump does not 
cycle

See 

Basic Troubleshooting

page 9

Basic mechanical problems

Paint is frozen or hardened in 
pump

Unplug sprayer from electrical outlet.

If paint is frozen in sprayer

:

Do NOT try to start sprayer until completely 
thawed or you may damage the motor, control 
board, and/or drivetrain.

1. Turn OFF power switch 
2. Place sprayer in warm area for several 

hours

3. Plug in and turn on sprayer
4. Slowly increase pressure until motor starts

If paint hardened in sprayer

:

1. Replace pump packings
2. Remove all residue from valves

Pump Service

, page 20.

Motor is damaged

Remove gear and try to rotate motor shaft by 
hand. See 

Motor Diagnostics

, page 19. If shaft 

will not turn, replace motor using 

Motor Kit

, page 

18.

Yoke is broken because pump 
is locked up due to dried paint 
or worn packings (XR9 only)

Repair or replace using 

Gear/Yoke Kit

, page 18.

Repair pump, page 20.

Summary of Contents for MAGNUM 232738

Page 1: ...tectural paints and coatings Specifications page 3 Related Manuals dx Pressure Roller Operation 3W9470 3X9470 3Y9470 3Z9470 XR9 Operation 3W9478 3X9478 3Y9478 3Z9478 SG3 Gun 309097 WL E ti2015b dx Pressure Roller Spray System Models 232736 232737 232738 Series B Important Safety Instructions Read all warnings and instructions in this manual Save these instructions XR9 Sprayer Models 232751 232752 ...

Page 2: ...1 General Problem Circuit Breaker is Tripping 13 General Problem Erratic Motor Operation 14 General Problem Low or Fluctuating Output 15 General Problem No Output 17 General Problem Excessive Pressure Build Up 17 List of Kits 18 Motor Diagnostics 19 Control Board Diagnostics 20 Pump Diagnostics 20 Pump Service 20 Parts 21 dx Pressure Roller Spray System 21 Pressure Roller Assembly 23 Parts 24 XR9 ...

Page 3: ...FPA 33 and OSHA requirements for the use of flammable and combustible materials WARNING WARNING a potentially hazardous situation which if not avoided could result in death or serious injury Warnings in the instructions usually include a symbol indicating the hazard Read the general Warnings section for additional safety information Hazard Symbol CAUTION CAUTION a potentially hazardous situation w...

Page 4: ...soline Do not plug or unplug power cords or turn lights on or off when flammable fumes are present Ground equipment and conductive objects in work area See Grounding instructions If there is static sparking or you feel a shock stop operation immediately Do not use equipment until you identify and correct the problem Keep a working fire extinguisher in the work area ELECTRIC SHOCK HAZARD Improper g...

Page 5: ... do not touch hot fluid or equipment Wait until equipment fluid has cooled completely PRESSURIZED ALUMINUM PARTS HAZARD Do not use 1 1 1 trichloroethane methylene chloride other halogenated hydrocarbon solvents or fluids containing such solvents in pressurized aluminum equipment Such use can cause serious chemical reaction and equipment rupture and result in death serious injury and property damag...

Page 6: ... been fully relieved after following the above steps VERY SLOWLY loosen the tip guard retaining nut or hose end coupling to relieve pressure gradually Then loosen it completely Clear tip or hose obstruction To help prevent injuries follow this procedure when you stop spraying and before you service or clean the sprayer remove parts or repair leaks ti2011 dx model XR9 model ti2018a ti2021a1 Leave P...

Page 7: ...olvent pails used when flushing follow local code Use only conductive metal pails placed on a grounded surface such as concrete Do not place the pail on a nonconductive surface such as paper or cardboard which interrupts grounding continuity Grounding the metal pail connect a ground wire to the pail by clamping one end to pail and other end to ground such as a water pipe To maintain grounding cont...

Page 8: ... the sprayer without the enclosure Replace if damaged Enclosures direct cooling air around the motor to prevent overheating They also reduce the risk of burns fire or explosion WARNING Page 4 CAUTION Do not run sprayer dry for more than 30 seconds Doing so could damage pump packings Protect internal drive parts of this sprayer from water Openings in enclosures allow for air cooling of mechanical p...

Page 9: ... Balls in check valve are stuck or check valves are damaged Clean or replace check valves See Pump Service page 20 Do not store in water Suction tube is leaking Tighten suction tube connection Inspect for other cracks or vacuum leaks Spray gun stopped spraying Spray tip is plugged Unplug spray tip Manual 309097 Pump cycles but does not build up pressure Pump is not primed Prime pump Inlet screen i...

Page 10: ... Use electrical generator with a proper voltage regulator Sprayer requires 220 240 VAC 50 60 Hz 1500 Watt generator Sprayer was operated at high pressure with very small tip which causes frequent motor starts and excessive heat build up Decrease pressure setting or increase tip size Building circuit breaker opens after sprayer operates for 5 to 10 minutes Too many appliances are plugged in on same...

Page 11: ...ed or you may damage the motor control board and or drivetrain 1 Turn OFF power switch 2 Place sprayer in warm area for several hours 3 Plug in and turn on sprayer 4 Slowly increase pressure until motor starts If paint hardened in sprayer 1 Replace pump packings 2 Remove all residue from valves Pump Service page 20 Motor is damaged Remove gear and try to rotate motor shaft by hand See Motor Diagno...

Page 12: ...re tester growler or perform spin test Motor Diagnostic page 19 If shorts are evident replace motor using Motor Kit page 18 Control board damaged CAUTION Do not perform control board diagnostics until you have determined the armature is good A bad armature can burn out a good control board See Control Board Diagnostics page 19 Replace control board if damaged using Control Board Kit page 18 Spraye...

Page 13: ...em Cause Solution General Problem Circuit Breaker is Tripping Specific Problem Cause Solution Building circuit breaker opens as soon as sprayer is turned on Sprayer electrical wiring is pinched or insulation is damaged Repair or replace any damaged wiring or terminals Securely reconnect wires Wires between pressure control switch and control board are pinched Motor armature is shorting Check for s...

Page 14: ...er electrical cord 2 Disconnect black control board wire at power switch 3 Check resistance of switch with ohmmeter 4 Reading must be infinity with power switch OFF 5 Reading must be zero with power switch ON 6 Replace power switch if damaged Also Basic Electrical Problems and Sprayer Wiring Problems page 12 Specific Problem Cause Solution General Problem Erratic Motor Operation Specific Problem C...

Page 15: ...too long or not heavy enough gauge Replace extension cord Grounding and Electrical Requirements page 7 Leads from motor or pressure switch to control board are damaged loose pinched or overheated Be sure terminals are centered and firmly connected Inspect for pinched wiring and wiring insulation and terminals for signs of overheating Replace any loose terminals or damaged wiring Securely reconnect...

Page 16: ...Spray Drain Valve Kit page 18 Spray pattern has variations pressure fluctuates excessively or motor runs very slowly Leads from motor or pressure switch to control board are damaged loose or overheated Be sure terminals are centered and firmly connected Inspect wiring insulation and terminals for signs of overheating Replace any loose terminals or damaged wiring Securely reconnect terminals Pressu...

Page 17: ...r dry out and retry Replace if necessary using Pressure Control Switch Kit page 18 General Problem Excessive Pressure Build Up Specific Problem Cause Solution Prime Spray Valve actuates automatically relieving pressure through drain tube Pressure control switch is worn Replace pressure control switch using Pressure Control Switch Kit page 18 Water or paint entered pressure control switch or shorte...

Page 18: ...oud Brace 287770 XR9 Series C Fan 245062 XR9 Shaft Gear Yoke Guides 245064 XR9 Front Cover with ID label 245667 XR9 Series A B Motor Drive Housing includes fan shroud brace 287784 XR9 Series C Motor Drive Housing includes fan 245595 XR9 Series A B Enclosure includes both sides labels and screws 287785 XR9 Series C Enclosure includes both sides labels and screws 245078 dx Pump Repair 245646 dx Moto...

Page 19: ...g electrical cord 3 Remove right enclosure Disconnect motor harness from control board 4 Remove fan brace 5 Remove four screws and front cover 6 Remove yoke and guide rods XR9 model only 7 Remove gear Armature Short Circuit Spin Test XR9 model only Quickly turn motor fan by hand There should not be electrical shorts and fan should coast two or three revolutions before stopping If fan does not spin...

Page 20: ...ge 18 If motor does not run replace control board repeat test Control Board Kit page 18 Pump Diagnostics When pump packings wear paint begins to leak down outside of pump Replace pump packings at the first sign of leaking or additional damage to drive train could occur Use Pump Repair Kit page 18 Pump Service If sprayer continues to cycle motor and pump run when the spray gun trigger is released o...

Page 21: ... KIT inlet valve 1 55 116295 CLAMP spring 88 dia 1 56 115478 SCREW machine pan head 2 57 245725 CORD Schuko CEE7 7 1 245726 CORD Italy 1 245727 CORD Denmark 1 245728 CORD Australia 1 245729 CORD Sweden 1 58 241922 HOSE paint 1 4 in x 25 ft 1 59 243238 GUN spray models 232736 232737 includes manual 309097 1 243382 GUN spray model 232738 includes manual 309097 1 61V 243308 KIT label warning 1 63 115...

Page 22: ... Roller Spray System Model 232736 232737 232738 WL E 43 ti2083a 42 44 50 63 53 30 32 38 54 23 52 55 64 13 12 5 13 3 69 2 16 19 15 18 57 70 71 72 73 63 51 7 58 63 56 61 61 59 75 41 31 1 1 Apply light coat of lithium based grease 76 ...

Page 23: ...sure Roller Assembly Model 245589 75a 15A586 TUBE extension 1 75b 245999 CAP end roller 1 75c 246277 CAP end roller 1 75d 15B065 CORE roller 1 75e 186678 BRUSH roller 9 in x 1 2 in nap 1 75f 197106 CLIP roller 1 a e b d c f ...

Page 24: ...ries C 1 67 195433 SUPPORT right Series A 1 15D923 SUPPORT right Series B C 1 68 195434 SUPPORT left Series A 1 15D924 SUPPORT right Series B C 1 69 195439 FRAME cart 1 70 195438 HANDLE cart 1 71 15D650 HOSE rack 2 72 116630 SCREW square shank 6 73 115480 KNOB t handle 2 74 195366 AXLE 1 75 195367 SPACER 2 76 115094 WHEEL 10 in 2 77 112612 CAP 2 78 105521 PLUG 2 80 195105 HANGER pail 1 83 115099 W...

Page 25: ...s A B ti2084 52 51 61 59 60 63 57 66 124 52 62 65 147 80 52 2 127 58 123 13 17 40 43 44 45 1 70 112 71 47 48 73 71 72 124 112 54 46 65 79 74 1 36 19 101 18 87 86 87 94 25 20 26 84 83 85 78 68 76 77 75 69 72 67 96 95 1 Apply light coat of lithium based grease 149 151 152 ...

Page 26: ...Parts 26 309477F XR9 Spray System Model 232751 232752 232753 Series C WL D ...

Page 27: ...an English Series A B 1 15G237 LABEL danger Chinese Korean English Series C 1 195834 LABEL danger English Spanish French Series A B 1 15G188 LABEL danger English Spanish French Series C 1 152 V 15A674 LABEL danger Italian Danish German Series A B 1 15G239 LABEL danger Italian Danish German Series C 1 15A676 LABEL danger Finnish Norwegian Swedish Series A B 1 15G241 LABEL danger Finnish Norwegian S...

Page 28: ...5 mesh 450 micron 35 mesh Wetted parts pump hose stainless steel brass ultra high molecular weight polyethylene UHMWPE carbide nylon aluminum PVC polypropylene fluroelastomer stainless steel brass leather ultra high molecular weight polyethylene UHMWPE carbide nylon aluminum PVC polypropylene fluroelastomer Wetted parts gun aluminum brass carbide nylon plated steel stainless steel UHMWPE zinc alum...

Page 29: ...T LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss sh...

Page 30: ...formation available at the time of publication Graco reserves the right to make changes at any time without notice MM 309477F Graco Headquarters Minneapolis International Offices Belgium China Japan Korea GRACO INC P O BOX 1441 MINNEAPOLIS MN 55440 1441 www graco com Rev 9 2006 309477F ...

Reviews: