Grounding Procedure (For Flammable Materials Only)

2

Installation

Grounding Procedure

(For Flammable Materials Only)

1.

Position striper so that the tires are not on pave-
ment.

2.

Ground sprayer with grounding clamp. Grounding
clamp must attach to grounded object (e.g. metal
sign post).

Pressure Relief Procedure

Before servicing the sprayer, pump pressure must be
relieved.

1.

Perform Grounding Procedure if using flammable
materials.

2.

Set pump switch to OFF. Turn engine OFF.

3. Turn pressure control to lowest setting. Trigger all

guns to relieve pressure.

4.

Engage all gun trigger locks. Turn prime valve
down.

5.

If you suspect the spray tip or hose is clogged or
that pressure has not been fully relieved:

a. VERY SLOWLY loosen the tip guard retaining

nut or the hose end coupling to relieve pressure

gradually.

b.

Loosen the nut or coupling completely.

c.

Clear the obstruction in the hose or tip.

FIRE AND EXPLOSION HAZARD

This equipment must be grounded to reduce the risk of

static sparking. Static sparking can cause fumes to
ignite or explode. Grounding provides an escape wire
for the electric current.

ti3306a

SKIN INJECTION HAZARD

This equipment stays pressurized until pressure is

manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing fluid
and moving parts, follow the Pressure Relief
Procedure 
when you stop dispensing and before
cleaning, checking, or servicing the equipment.

Summary of Contents for LineLazer V Standard Series

Page 1: ...or installation of a Battery and Charging System on LineLazer V Standard Series For professional use only Important Safety Instructions Read all warnings and instructions in this manual and in the equ...

Page 2: ...spect the spray tip or hose is clogged or that pressure has not been fully relieved a VERY SLOWLY loosen the tip guard retaining nut or the hose end coupling to relieve pressure gradually b Loosen the...

Page 3: ...Remove Cover Installation 3 Remove Cover ti28697a...

Page 4: ...azer V 3900 5900 200HS Kit 25A526 Charging Board Installation Ref Part Description Qty 7 25A495 KIT repair charger board 1 9 106520 SCREW thd forming pnh 5 109 17J123 PLATE cover 1 114 128978 SCREW ma...

Page 5: ...00HS Kit 25A526 12V 22 AH Battery Installation Ref Part Description Qty 1 16U160 BATTERY 22 AH sealed 1 2 17H644 SHELF battery 1 3 126949 STRAP battery 1 4 107257 SCREW thd forming 4 5 111307 WASHER l...

Page 6: ...Connect Battery and Install Cover 6 Installation Connect Battery and Install Cover ti28520a...

Page 7: ...LineLazer V 3900 5900 200HS Installation 7 LineLazer V 3900 5900 200HS Kit 25A526 Wiring Diagram RED BLACK BLACK RED CHARGER BOARD 24Y443 HP AUTO 30A AUTOMOTIVE FUSE REGULAR ATO FUSE HOLDER ti28413a...

Page 8: ...hanges at any time without notice 2ULJLQDO LQVWUXFWLRQV This manual contains English MM 3A3456 Graco Headquarters Minneapolis International Offices Belgium China Japan Korea GRACO INC AND SUBSIDIARIES...

Reviews: