Maintenance - Fusion MMA PC Gun
3A9099A Operation, Repair, Parts
47
Flush Gun
If it is necessary to flush gun, use following procedure.
1. Follow
2. Flush with acetone into a grounded metal pail,
holding a metal part of fluid manifold firmly to side
of pail. Use the lowest possible fluid pressure when
flushing.
Clean Spray Tip Adapter and
Mix Chamber Nozzle
1. Engage Piston Safety Lock.
2. Refer to
Table 1: Nozzle Drill Bit Sizes
Also see identification chart under
page 68. Use the appropriate size drill bit to clean
Mix Chamber (13). If necessary, clean Spray Tip
Adapter (3) gently with stiff brush. If necessary,
remove Spray Tip Adapter and clean Mix Chamber
with drill bit.
Table 1: Nozzle Drill Bit Sizes
Flat Spray
Mix Chamber
Part No.
Drill Size in. (mm)
PC29FL
3/32, .094 (2.35)
13
3