Meter Setup and Operation Instructions
3A1451C
13
3.
Press and hold the Total but-
ton again to display the
non-resettable total (F
IG
. 18).
NOTE: Each time you press and
hold the Total button the display
toggles between the non-resetta-
ble and resettable totals.
4.
Press and hold the Reset but-
ton. The unit returns to Stan-
dard Dispense Mode.
Error Code
If an error code is shown on the
display, as shown in F
. 19, you
can press the Reset button to
clear the error code and view the
dispensed amount. Even in an
error condition, the unit keeps
track of the amount dispensed.
Setup
Terms
The following terms are shown on the display and/or
used often in this instruction manual.
•
R-TOTAL: Resettable Total
Shows the cumulative amount that has been dis-
pensed in all modes. Can be reset to zero.
•
TOTAL: Non–resettable Total
Shows the cumulative amount that has been dis-
pensed in all modes for the life of the unit. Cannot
be reset.
•
Manual Mode
Dispense mode in which display counts up from
zero to show the dispensed amount.
•
Auto Mode
Dispense mode in which a preset, user–entered
amount is dispensed. When the preset amount is
dispensed, the trigger unlocks to stop the unit from
dispensing and the amount dispensed is displayed.
At this point, you may dispense more by pulling back
the trigger, and the display resumes counting up.
•
Asleep / Awake Mode
Asleep is a battery–saving mode in which the dis-
play goes blank after 45 seconds of inactivity. The
display comes Awake from sleep mode when you
press any button or squeeze the trigger to dispense
fluid.
F
IG
. 19
Error
Code
Cause Solution
Err 1
Flow rate is higher
than 5 gpm.
Adjust the flow rate so it is
not higher than 5 gpm.
Air was pumped
through the line.
Purge air from the line.
*$/