Troubleshooting

333276A

5

Troubleshooting 

Problem

Cause

Solution

No module status LEDs are illumi-
nated.

No power to cellular module.

Turn Reactor ON.

Ensure unit is properly installed. 
See 

Installation

 on page 3.

Make sure the M8, 4-pin to M12, 
8-pin cable is installed between cel-
lular module and control box.

Has not identified GPS location 
(green module status LED flashing).

Still identifying location.

Wait a few minutes for the unit to 
identify the location.

Unable to identify location. In a 
location where GPS lock cannot 
occur. Buildings and warehouses 
often prevent GPS locks. 

Move system to a location with a 
clear view of the sky.

Has not established a cellular con-
nection (orange module status 
flashing).

Still establishing cellular connection.

Wait a few minutes for unit to estab-
lish the connection.

Unable to establish cellular connec-
tion.

Move system to a location with cel-
lular service to establish cellular 
connection.

Cannot view data for my unit(s) on 
website.

Graco InSite unit has not been acti-
vated.

Activate unit. See 

Registering and 

Activating the Graco InSite

 on 

page 4.

Temperature data not displayed on 
website.

Reactor temperature measurement 
is not working.

See Reactor repair manual.

Hose zone temperature data not 
displayed on website.

The RTD is not correctly installed 
on the hose or is broken.

See Reactor repair manual.

Pressure data not displayed on 
website.

Reactor pressure measurement is 
not working.

See Reactor repair manual.

Summary of Contents for InSite 24T280

Page 1: ...pressure pressure setpoint cycles and GPS location from a Reactor 2 E 30 or E XP2 proportioner For professional use only Not approved for use in explosive atmospheres or hazardous locations Model 24T...

Page 2: ...symbols appear in the body of this manual or on warning labels refer back to these Warnings Product specific hazard symbols and warnings not covered in this section may appear throughout the body of...

Page 3: ...llular module 1 connector 3 Route cellular module cable 2 through wire tie 3 to MCM B Secure with wire ties 4 as needed 4 Connect other end of cellular module cable 2 to MCM B connector 14 NOTICE To p...

Page 4: ...l number from the cel lular module below Verify Module Status To check the status of the cellular module locate the status LEDs on the module then refer to the following chart LED Status Description G...

Page 5: ...the sky Has not established a cellular con nection orange module status flashing Still establishing cellular connection Wait a few minutes for unit to estab lish the connection Unable to establish ce...

Page 6: ...6 333276A Parts Ref Part Description Qty 1 16X118 MODULE cellular and GPS 1 2 16V801 CABLE M8 4 pin female to M12 8 pin male 9 8 ft 3 m 1 3 127377 TIE cable 6 in 1 125871 TIE cable 7 5 in 3 FIG 2 WL...

Page 7: ...emote Reporting Installation Kit US Metric Operating Temperature 22 to 167 F 30 to 75 C Storage Temperature 40 to 185 F 40 to 85 C Ambient Temperature during Battery Charging 41 to 104 F 5 to 40 C FCC...

Page 8: ...r workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRES...

Reviews: