Warnings 

4

313839F

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back 
to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where 
applicable.

WARNING

FIRE AND EXPLOSION HAZARD 

When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be 
aware that flammable fumes can ignite or explode. To help prevent fire and explosion:

Use equipment only in well ventilated area.

Eliminate all ignition sources, such as cigarettes and portable electric lamps. 

Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline.

Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.

Ground all equipment in the work area.

Use only grounded hoses.

If there is static sparking or you feel a shock, 

stop operation immediately.

 Do not use equipment 

until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

ELECTRIC SHOCK HAZARD 

This equipment must be grounded. Improper grounding, setup, or usage of the system can cause 
electric shock.

Turn off and disconnect power at main switch before disconnecting any cables and before servicing 
equipment.

Connect only to grounded power source.

All electrical wiring must be done by a qualified electrician and comply with all local codes and 
regulations.

PRESSURIZED EQUIPMENT HAZARD 

Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and 
cause serious injury.

Follow 

Pressure Relief Procedure

 in this manual, when you stop spraying and before cleaning, 

checking, or servicing equipment. 

Tighten all fluid connections before operating the equipment.

Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

EQUIPMENT MISUSE HAZARD 

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system 
component. See 

Technical Data

 in all equipment manuals.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-
facturer’s replacement parts only.

Do not alter or modify equipment.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

Summary of Contents for Injecto-Flo II Single Line

Page 1: ...meters in a single line system Not for use in hazardous locations Part No See page 2 OIL 435 psi 3 0 MPa 30 bar Maximum Working Pressure GREASE 580 psi 4 0 MPa 40 bar Maximum Working Pressure Importa...

Page 2: ...Dual w DIN Straight Connector 10 pipe 122558 0 8 3 0 0 13 0 5 Dual w DIN Screw Cap 122559 0 8 3 0 0 13 0 5 Dual w DIN Straight Connector 10 pipe 122560 0 8 3 0 0 05 0 2 Dual w M12 Top Screw Cap 122561...

Page 3: ...w Cap 122582 0 8 3 0 0 05 0 2 Single w DIN Screw Cap 122583 0 8 3 0 0 05 0 2 Single w DIN Straight Connector 10 pipe 122584 0 8 3 0 0 05 0 2 Single w M12 Top Screw Cap 122585 0 8 3 0 0 05 0 2 Single w...

Page 4: ...e electric shock Turn off and disconnect power at main switch before disconnecting any cables and before servicing equipment Connect only to grounded power source All electrical wiring must be done by...

Page 5: ...y providing an escape wire for the electrical current due to static build up or in the event of a short circuit Pressure Relief Procedure To relieve pressure loosen outlet fitting connection to bleed...

Page 6: ...Models A Tank B Electric Motor C Gear Pump D Electric Level Switch E Pressure Limiting Valve F Relief Valve G Filling Cap Filter H Pressure Outlet Oil Models includes all items A H and also the follow...

Page 7: ...Installation 313839F 7 Refilling Options Level Switch Connector Options FIG 2 FIG 3...

Page 8: ...f these units is external without control programming by the machine automatism or external control CNC Automatic device etc It can be equipped with an electrical level minimum level control in the ta...

Page 9: ...2906 SWITCH min pre alarm level w din 6L 3 122907 SWITCH min level w M12 top connec tor 3L 122908 SWITCH min level w M12 top connec tor 6L 122909 SWITCH min pre alarm level w M12 top connector 3L 1229...

Page 10: ...2921 SWITCH min M12 top connector 6L 4 122911 RESERVOIR 3 Liter no cover NA RESERVOIR 6 Liter no cover 5 122912 CAP screw 4 5 3 2 1 Ref Part No Description 1 122916 PUMP electric motor grease 3L 12291...

Page 11: ...Parts Special Fluid Grease 313839F 11 Dimensions 3 Liter Tanks...

Page 12: ...Parts Special Fluid Grease 12 313839F Dimensions 6 Liter Tanks...

Page 13: ...MPa 30 bar Grease 580 psi 4 0 MPa 40 bar Working Temperature Lubricant 140 F 60 C Ambient Oil models only 104 F 40 C A C Motor Voltage Frequency 230 400 VAC 50 60 Hz 0 5 0 3A Consumption 70W RPM 50Hz...

Page 14: ...any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF AN...

Reviews: