The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back 
to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where 
applicable.

WARNING

FIRE AND EXPLOSION HAZARD 

When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be 
aware that flammable fumes can ignite or explode. To help prevent fire and explosion:

Use equipment only in well ventilated area.

Eliminate all ignition sources, such as cigarettes and portable electric lamps. 

Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline.

Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.

Ground all equipment in the work area.

Use only grounded hoses.

If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment 
until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

ELECTRIC SHOCK HAZARD 

This equipment must be grounded. Improper grounding, setup, or usage of the system can cause 
electric shock.

Turn off and disconnect power at main switch before disconnecting any cables and before servicing 
equipment.

Connect only to grounded power source.

All electrical wiring must be done by a qualified electrician and comply with all local codes and 
regulations.

PRESSURIZED EQUIPMENT HAZARD 

Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and 
cause serious injury.

Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, 
checking, or servicing equipment. 

Tighten all fluid connections before operating the equipment.

Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

EQUIPMENT MISUSE HAZARD 

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system 
component. See Technical Data in all equipment manuals.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-
facturer’s replacement parts only.

Do not alter or modify equipment.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

Summary of Contents for Injecto-Flo II 122545

Page 1: ...single line system Not for use in hazardous locations Part No See page 2 OIL 435 psi 3 0 MPa 30 bar Maximum Working Pressure GREASE 580 psi 4 0 MPa 40 bar Maximum Working Pressure Important Safety In...

Page 2: ...Dual w DIN Straight Connector 10 pipe 122558 0 8 3 0 0 13 0 5 Dual w DIN Screw Cap 122559 0 8 3 0 0 13 0 5 Dual w DIN Straight Connector 10 pipe 122560 0 8 3 0 0 05 0 2 Dual w M12 Top Screw Cap 122561...

Page 3: ...ap 122583 0 8 3 0 0 13 0 2 Single w DIN Straight Connector 10 pipe 122584 0 8 3 0 0 13 0 2 Single w M12 Top Screw Cap 122585 0 8 3 0 0 13 0 2 Single w M12 Top Straight Connector 10 pipe 122586 0 8 3 0...

Page 4: ...e electric shock Turn off and disconnect power at main switch before disconnecting any cables and before servicing equipment Connect only to grounded power source All electrical wiring must be done by...

Page 5: ...y providing an escape wire for the electrical current due to static build up or in the event of a short circuit Pressure Relief Procedure To relieve pressure loosen outlet fitting connection to bleed...

Page 6: ...A Tank B Electric Motor C Gear Pump D Electric Level Switch E Pressure Limiting Valve F Relief Valve G Filling Cap Filter H Pressure Outlet Oil Models includes all items A H and also the following J...

Page 7: ...on B Elbow Connector Option C Screw Cap D Strainer Basket Oil Models Only E Down Tube Oil Models Only F Vent additional information G Elbow Connector Vent FIG 4 NOTE A vent is included with all units...

Page 8: ...tor Top Entry Option Minimum level with M12 connector top entry Minimum Premalarm level with M12 connector top entry Instructions The control of these units is external without control programming by...

Page 9: ...Electrical Diagram 313839C 9 Electrical Diagram PNP BN BK BU W2 U2 V2 U1 V1 W1 L1 L2 L3 W2 U2 V2 W2 U2 V2 L1 L2 L3 L1 N U1 V1 W1 U1 V1 W1 2 3 1 MIN MIN 2 PRE 1 3 Oil Grease...

Page 10: ...13 FILTER refilling 122914 FILTER suction 3L reservoir 122915 FILTER suction 6L reservoir 122916 PUMP electric motor grease 3L 122917 PUMP electric motor grease 6L 122918 SWITCH min level w din 3L 122...

Page 11: ...Connection M14 x 1 5 Pump Lubricant Models Oil Mineral or synthetic oil Models Grease Fluid grease NLGI00 000 Flow 0 05 0 13 gal min 0 2 0 5 L min Maximum Pressure Oil 435 psi 3 0 MPa 30 bar Grease 58...

Page 12: ...Technical Data 12 313839C Dimensions _ _ 289 mm 11 3 in 5 59 in 142 mm 136 5 mm 152 5 mm 6 in 5 37 in 8 6 9 0 in 220 230 mm 9 65 in 245 mm...

Page 13: ...Notes 313839C 13 Notes...

Page 14: ...erial or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES...