Technical Specifications
306817N
15
Technical Specifications
California Proposition 65
10:1 President Pump Hydra-Clean
®
Units
US
Metric
Air pressure operating range
20 to 120 psi
1.5 to 8.5 bar (150 to 850 kPa)
Pump ratio
10:1
Recommended cycle rate for continuous duty
60 cycles per minute, or 3 gpm
Pump discharge pressure
1200 psi)
83 bar, 8.3 MPa
Air volume requirements
Without spray tip
23 cfm at 70 psi
0.64 m
3
/minute
at 4.8 bar (480 kPa)
With 0.062 in. spray tip, included with unit
32 cfm at 100 psi
0.90 m
3
/minute
at 6.9 bar (690 kPa)
Weight
All models
55 lb
24.95 kg
Noise (dBa)
Sound pressure level*
83 dBa at 100 psi (6.8 bar, 0.68 MPa)—40 cycles/minute (at
one meter)
Sound power level**
96 dBa at 100 psi (6.8 bar, 0.68 MPa)—40 cycles/minute
*Sound pressure measured 3.37 feet (1 meter) from equipment.
**Sound power measured per ISO-9614-2.
CALIFORNIA RESIDENTS
WARNING: Cancer and reproductive harm – www.P65warnings.ca.gov.