background image

Installation

309815T

7

Installation

F

IG

. 1. Installation

246655 Package shown installed in Reactor proportioning system.
Includes * parts only.

TI7690A

C*

2*

2*

*2

101* (ISO)

*101 (RES)

102*

*102

304*

103* (Ref)

*103 (Ref)

D

2

Air Supply Kit. See 309827.

2

2

2

2

NOTE:

System shown

includes 246978 Circulation
Kit, available separately,
which includes two 247616
desiccant dryers (6).

6*

Summary of Contents for Husky 716 series

Page 1: ...e explosive atmospheres Important Safety Instructions Read all warnings and instructions in this manual Save these instructions See page 2 for a list of feed pump kits TI7690A 246655 Feed Pump Package...

Page 2: ...Pump Model Maximum Air Input Pressure Maximum Fluid Working Pressure 246369 246366 Husky 515 100 psi 0 7 MPa 7 bar 100 psi 0 7 MPa 7 bar 246375 246367 Husky 716 100 psi 0 7 MPa 7 bar 100 psi 0 7 MPa...

Page 3: ...o Pump 312766 T1 2 1 Ratio Pump 3A5180 T3 3 1 Ratio Pump Reactor Electric Proportioner Part No Description 312065 Reactor Electric Proportioner Operation Manual English 312066 Reactor Electric Proport...

Page 4: ...Use only Graco parts and accessories Do not exceed the maximum working pressure or temperature rating of the lowest rated system component See Technical Data in all equipment manuals Use fluids and so...

Page 5: ...lied with desiccant dryer 6 Screw dryer 3 4 npt fitting into vent of A component ISO drum c Open drum bung hole d Place riser tube into drum Tighten bung adapter 304 securely WARNING Read warnings pag...

Page 6: ...anual supplied b Reactor see Reactor operation manual c Spray gun see gun manual d Fluid supply containers follow your local code e Object being sprayed follow your local code f Solvent pails used whe...

Page 7: ...nstalled in Reactor proportioning system Includes parts only TI7690A C 2 2 2 101 ISO 101 RES 102 102 304 103 Ref 103 Ref D 2 Air Supply Kit See 309827 2 2 2 2 NOTE System shown includes 246978 Circula...

Page 8: ...Installation 8 309815T Installation with Circulation T3 Pumps FIG 2 RES B ISO A WL D NOTE System shown includes 246978 Circulation Kit available separately which includes two 247616 desiccant dryers 6...

Page 9: ...o top of riser tube kit 202 7 Connect suction hose 203 to elbow 206 and inlet swivel 205 8 Follow steps 1 7 pages 5 6 to finish installation Standard 2 1 Kit 1 Follow steps 1 3 page 5 2 Open drum bung...

Page 10: ...ove any air Do not let material harden in pump Shutdown See Shutdown and Pressure Relief Procedure in Reactor manual Close feed pump bleed type master air valve Changing Drums 1 See Shutdown 2 Remove...

Page 11: ...246483 AIR SUPPLY KIT see 309827 1 3 100206 BUSHING air inlet 1 2 npt m x 1 4 npt f 246376 only see page 15 for location 2 6 247616 KIT desiccant dryer for ISO side 1 7 104969 BUSHING reducer 1 2npt m...

Page 12: ...ISO side see page 11 1 Ref Part Description Qty 1 247956 KIT fluid supply 1 1a 256200 PUMP 2 1 see 312766 2 1b 217382 HOSE fluid 3 4 npt mbe 3 4 in 19 mm ID 10 ft 3 05 m nylon 2 1c 113344 FITTING swiv...

Page 13: ...676 2 246654 PUMP KIT Triton 308 246677 2 102 157785 UNION swivel 3 4 npt m x 3 4 npsm f 246481 and 246482 2 202965 UNION swivel 1 in npt m x 3 4 npsm f 246676 2 113344 UNION swivel 1 2 npt m x 3 4 np...

Page 14: ...ed with oil To order replacement parts and repair kits refer to the Husky 515 parts list in manual 308981 201 202 Ref Part Description Qty 201 246485 PUMP Husky 716 see 308981 and read CAUTION below 1...

Page 15: ...202965 UNION swivel pump inlet 1 in npt m x 3 4 npsm f 1 206 107409 ELBOW swivel riser tube 90 1 in npt m x 3 4 npsm f 1 CAUTION 647673 Husky 1050 Pump is built specifically for use with isocyanates...

Page 16: ...02 156592 TUBE riser 1 303 106537 GASKET bung 1 304 15B728 ADAPTER bung 1 305 15B727 FITTING 1 in npt 1 306 15B921 SPACER 1 307 100279 BALL 1 308 159100 RETAINER ball 1 309 110831 O RING 1 TI3445a 301...

Page 17: ...2 1 Ratio 180 psi 1 2 MPa 12 5 bar Maximum fluid working pressure Husky 515 100 psi 0 7 MPa 7 bar Husky 716 100 psi 0 7 MPa 7 bar Husky 1050 125 psi 0 86 MPa 8 6 bar Triton 308 115 psi 0 8 MPa 8 bar...

Page 18: ...pairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INC...

Reviews: