background image

Dimensions

Dimensions

Dimensions

Dimensions

A

A

A

B

B

B

C

C

C

58.00 in. (1473 mm)

17.00 in. (432 mm)

19.88 in. (505 mm)

20

3A6358A

Summary of Contents for HiP e710

Page 1: ...action extraction extraction For For For professional professional professional use use use only only only Important Important Important Safety Safety Safety Instructions Instructions Instructions Read all warnings and instructions in this manual Save Save Save these these these instructions instructions instructions See Technical Specifications for Maximum Working Pressure See page 3 for model pa...

Page 2: ...ent 11 Operation 12 Startup 12 Shutdown 12 Pressure Relief Procedure 12 Flushing 12 Maintenance 13 Preventive Maintenance Schedule 13 Change the Oil 13 Check Oil Level 13 Bearing Pre Load 13 Wet Cups 13 Troubleshooting 14 Repair 15 Dura Flo Lowers 15 Reassemble the Coupling Adapter and Tie Rods to the Motor 16 Parts 17 Dura Flo Pump Assembly 17 Pump Matrix 19 Dimensions 20 Mounting Hole Patterns 2...

Page 3: ...dvanced EDEN01 220 CC Basic EDEN02 220 CC Advanced EDEN03 145 CC Basic 220 EDEN04 145 CC Advanced ATEX FM IECEx Stainless Steel PTFE UH MWPE Pumps Pumps Pumps with with with Basic Basic Basic Motors Motors Motors Pumps Pumps Pumps with with with Advanced Advanced Advanced Motors Motors Motors II II II 2 2 2 G G G Ex Ex Ex db db db h h h IIA IIA IIA T3 T3 T3 Gb Gb Gb X X X II II II 2 1 2 1 2 1 G G ...

Page 4: ...r unplug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggering into pail Do not use pail liners unless they are antistatic or conductive Stop Stop Stop operation operation operation immediately immediately immediately if static sparking occurs or you feel a shock Do not use equipment u...

Page 5: ...vers removed Pressurized equipment can start without warning Before checking moving or servicing equipment follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure and disconnect all power sources SKIN SKIN SKIN INJECTION INJECTION INJECTION HAZARD HAZARD HAZARD High pressure fluid from dispensing device hose leaks or ruptured components will pierce skin This may lo...

Page 6: ...mperature rating of the lowest rated system component See Technical Technical Technical Specifications Specifications Specifications in all equipment manuals Use fluids and solvents that are compatible with equipment wetted parts See Technical Technical Technical Specifications Specifications Specifications in all equipment manuals Read fluid and solvent manufacturer s warnings For complete inform...

Page 7: ...wall for the mounting bracket The wall should be capable of supporting the pump and accessories that will be attached to the bracket any additional weight of the fluid used in the pump and any stress or strain that may be applied during pump operation 2 Drill four 7 16 in 11 mm diameter holes for the mounting bolts approximately 5 ft 1 5 m above the floor using the wall bracket as a template Use a...

Page 8: ...ll National State and Local electric codes All cable glands and cables must be rated at 70 C 158 F Typical Typical Typical Installation Installation Installation NON NON NON HAZARDOUS HAZARDOUS HAZARDOUS AREA AREA AREA HAZARDOUS HAZARDOUS HAZARDOUS AREA AREA AREA Figure 1 Typical Installation Key Key Key for for for Fig Fig Fig 1 1 1 A Electrical Supply must be sealed conduit approved for use in h...

Page 9: ... use in hazardous locations 3 Open the electrical compartment S on the motor 4 Bring the supply wires into the electrical compartment through the 3 4 14 npt f inlet port Connect the wires to the terminals as shown in Figs 3 and 4 Torque the terminal nuts to 25 in lb 2 8 N m maximum Do Do Do not not not over torque over torque over torque Figure 3 Connect the Power Wires Single Phase Figure 4 Conne...

Page 10: ...ry The Control Module Accessory is required with Advanced E Flo DC motors to provide the interface for users to enter selections and view information related to setup and operation See the Control Module Accessory Kit manual for installation and operation information Fluid Fluid Fluid Line Line Line Accessories Accessories Accessories Install the following accessories as shown in Fig 1 using adapt...

Page 11: ...t and waste container To avoid static sparking and injury from splashing always flush at the lowest possible pressure The pump fluid section was tested with lightweight oil which is left in the fluid passages to protect parts To avoid contaminating your fluid with oil flush the equipment with a compatible solvent before using the equipment 3A6358A 11 ...

Page 12: ...s symbol This equipment stays pressurized until pressure is manually relieved To help prevent serious injury from pressurized fluid such as skin injection splashing fluid and moving parts follow the Pressure Relief Procedure when you stop spraying and before cleaning checking or servicing the equipment 1 Disengage the start stop control C See Fig 1 2 Shut off and lock out the fused safety switch B...

Page 13: ...d Graco Part No 16W645 ISO 220 silicone free synthetic gear oil Check the oil level in the sight glass K Fill until the oil level is near the halfway point of the sight glass The oil capacity is approximately 1 5 quarts 1 4 liters Do Do Do not not not overfill overfill overfill 5 Reinstall the fill cap 6 Reconnect power Figure 7 Oil Drain Plug Check Check Check Oil Oil Oil Level Level Level See Fi...

Page 14: ...on both strokes Worn piston packing Replace See lower manual Held open or worn ball check valves Check and repair See lower manual Pump output low on only one stroke Worn piston packing Replace See lower manual No output Improperly installed ball check valves Check and repair See lower manual Exhausted fluid supply Refill and reprime pump Held open or worn ball check valves Check and repair See lo...

Page 15: ...coupling adapter 9 and tie rods 6 have been disassembled from the motor 3 see Reassemble the Coupling Adapter and Tie Rods to the Motor page 16 1 Assemble the coupling nut 11 to the piston rod R See Fig 8 2 Orient the lower 7 to the motor 3 Position the lower 7 on the tie rods 6 Lubricate the threads of the tie rods 6 3 Screw the tie rod locknuts 8 onto the tie rods 6 Tighten the locknuts 8 and to...

Page 16: ...apter 9 and tie rods 6 have been disassembled from the motor 3 to ensure proper alignment of the motor shaft to the piston rod R 1 See Fig 10 Screw the tie rods 6 into the motor 3 and torque to 50 60 ft lb 68 81 N m 2 Screw the coupling adapter 9 into the motor shaft and torque to 90 100 ft lb 122 135 N m 3 Reassemble the pump to the motor Use the applicable instructions for your pump Dura Flo pag...

Page 17: ...Parts Parts Parts Parts Dura Dura Dura Flo Flo Flo Pump Pump Pump Assembly Assembly Assembly See Models page 3 for an explanation of the pump part number 3A6358A 17 ...

Page 18: ...5 OIL gear synthetic ISO 220 silicone free 1 quart 0 95 liter not shown 2 4 See Pump Matrix page 19 WASHER 4 5 See Pump Matrix page 19 BOLT 4 6 15H562 ROD tie 3 7 See Pump Matrix page 19 PUMP displacement see lower manual 1 8 101712 NUT lock 3 9 15H370 ADAPTER 1 10 184129 COLLAR coupling 2 11 186925 NUT coupling 1 12 See Pump Matrix page 19 STAND floor 1 34 See Pump Matrix page 19 FITTING 1 35 24S...

Page 19: ...ef Ref 12 12 12 Motor Motor Motor Ref Ref Ref 3 3 3 Washer Washer Washer Ref Ref Ref 4 4 4 Bolt Bolt Bolt Ref Ref Ref 5 5 5 Lower Lower Lower Pump Pump Pump Ref Ref Ref 7 7 7 Fitting Fitting Fitting Ref Ref Ref 34 34 34 30H000 EM0070 30H001 EM0071 L220SS 15M805 30H002 EM0070 30H003 EM0071 241177 190724 EDEN01 EM0070 EDEN02 EM0071 L220SS 15M805 EDEN03 EM0070 EDEN04 A 255143 256193 EM0071 100133 100...

Page 20: ...Dimensions Dimensions Dimensions Dimensions A A A B B B C C C 58 00 in 1473 mm 17 00 in 432 mm 19 88 in 505 mm 20 3A6358A ...

Page 21: ...ing Mounting Hole Hole Hole Patterns Patterns Patterns Stand Stand Stand Mount Mount Mount Dimension Dimension Dimension Measurement Measurement Measurement A 19 88 in 505 mm B 14 50 in 368 mm C 16 88 in 429 mm D 17 00 in 432 mm 3A6358A 21 ...

Page 22: ...nt A 17 8 in 451 mm B 14 5 in 368 mm C 12 4 in 314 mm D 9 0 in 229 mm E 5 4 in 137 mm F 7 4 in 187 mm G 5 3 in 133 mm H 2 0 in 51 mm J 1 0 in 25 mm K 1 6 in 41 mm L 2 7 in 69 mm M 4 4 in 112 mm N Four 0 562 in 14 mm diameter holes for mounting to stand P Four 0 438 in 11 mm diameter holes for mounting to wall 22 3A6358A ...

Page 23: ...tor operating at 100 70 and 40 psi Pressure Pressure Pressure Max Pressure A 70 Pressure B 40 Pressure C Motor Motor Motor Amps Watts Amps Watts Amps Watts Max Pressure A 70 Pressure B 40 Pressure C Table Table Table 2 2 2 220 220 220 V V V DC DC DC Motor Motor Motor with with with Dura Dura Dura Flo Flo Flo 145 145 145 Lower Lower Lower CYCLES CYCLES CYCLES PER PER PER MINUTE MINUTE MINUTE 0 400 ...

Page 24: ...2 8 28 600 4 1 41 200 1 4 14 800 5 5 55 1000 6 9 69 1200 8 3 83 1400 9 7 97 1600 10 0 1 10 1800 12 4 124 0 0 0 200 400 600 800 1000 1200 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 2 8 15 21 0 0 0 2 0 76 0 4 1 52 0 6 2 28 0 8 3 04 1 0 3 80 1 2 4 56 2000 13 8 138 B C A B C A MOTOR MOTOR MOTOR AMPS AMPS AMPS WATTS WATTS WATTS FLUID FLUID FLUID PRESSURE PRESSURE PRESSURE psi bar MPa FLUID FLUID FLUID FLOW FLOW F...

Page 25: ... the pump lower See Performance Charts page 23 Input Input Input voltage voltage voltage 200 250 Vac single phase 50 60 Hz Input Input Input current current current 20 A maximum Power Power Power inlet inlet inlet port port port size size size 3 4 14 npt f Ambient Ambient Ambient temperature temperature temperature range range range 32 104 F 0 40 C Sound Sound Sound data data data Less than 70 dB ...

Page 26: ...D AND AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AND AND FITNESS FITNESS FITNESS FOR FOR FOR A A A PARTICULAR PARTICULAR PARTICULAR PURPOSE PURPOSE PURPOSE IN IN IN CONNECTION CONNECTION CONNECTION WITH WITH WITH ACCESSORIES ACCESSORIES ACCESSORIES EQUIPMENT EQUIPMENT EQUIPMENT ...

Reviews: