Technical Data
20
311831E
Technical Data
NXT Air-Powered Pumps
Performance Charts
To find Fluid Outlet Pressure (psi/MPa/bar) at a spe-
cific fluid flow (lpm/gpm) and operating hydraulic pres-
sure (psi/MPa/bar):
1.
Locate desired flow along bottom of chart.
2.
Follow vertical line up to intersection with selected
fluid outlet pressure curve (black). Follow left to
scale to read fluid outlet pressure.
Key
Model
Maximum
Working Pressure
psi (MPa, bar)
Maximum
Air Input Pressure
psi (MPa, bar)
Air Consumption
Fluid Flow at
60 cycles per
minute
gpm (lpm)
Pump Cycles
per Gallon
(Liter)
Maximum
Fluid
Temperature
Rating
°F (°C)
JX33XX
330 (2.3, 23)
100 (0.7, 7.0)
See Performance Charts
63 (237)
0.93 (0.24)
150° (66°)
JX44XX
440 (3.0, 30)
100 (0.7, 7.0)
47 (178)
1.3 (0.34)
JX60XX
500 (3.4, 34)
75 (0.52, 5.2)
31 (118)
1.93 (0.5)
A
0.5 MPa, 4.9 bar (70 psi) air pressure
B
0.37 MPa, 3.7 bar (55 psi) air pressure
C
0.3 MPa, 2.8 bar (40 psi) air pressure
Test Fluid: No. 10 Weight Oil
NXT 6500 with 2000cc Lower Pumps (JX60XX)
Fl
ui
d Pres
su
re
A
B
psi (MPa, bar)
500 (3.44, 34.4)
450 (3.10, 31.0)
400 (2.75, 27.5)
350 (2.41, 24.1)
300 (2.06, 20.6)
200 (1.37, 137)
100 (0.68, 68)
0
Fluid Flow in gpm (lpm)
20
(75.7)
C
A
B
C
Air Flo
w
(s
cfm)
20
40
60
80
100
120
30
(113.5)
140
25
(94.6)
5
(18.9)
10
(37.8)
15
(56.7)
35
(132.4)
50 (0.34, 3.4)
150 (1.03, 10.3)
250 (1.72, 17.2)
160
Summary of Contents for High-Flo Viscount II