Run Mode
313855K
39
Pump Off Ended with Machine Counts
If the Pump Off sequence has been programmed to be
ended by MACHINE COUNTS:
•
The GLC 4400 pump output relay activates (J7-3)
and will stay off until the correct number of counts
(J6-15) occur (see Setup Menus, Pump Off, page
26).
•
The Pump On LED (A) remains off during this time.
•
The Pump Off icon (C) displays.
•
The Cycle LED (B) and Machine Count icon (D) dis-
play and indicate the Machine Count Switch activa-
tion.
Pump Off Ended with Machine Counts; Max
Time Entered
If the Pump Off sequence has been programmed to be
ended by MACHINE COUNTS with a maximum time:
•
The GLC 4400 pump output relay activates (J7-3)
and will stay off until the correct number of counts
(J6-15) occur (see Setup Menus, Pump Off, page
26).
•
The Pump On LED (A) remains off during this time.
•
The Pump Off icon (C) displays.
•
The Cycle LED (B) and Machine Count icon (D) dis-
play and indicate the Machine Count Switch activa-
tion.
•
The counts indicator bar (E) displays a visual repre-
sentation
of the machine counts received.
•
If the set number of machine counts is not received
before time expires, an alarm occurs.
F
IG
. 61
A
B
C
D
F
IG
. 62
A
C
E
D
B