For Single-Line Parallel Automatic Lubrication Systems. For professional use only.
Part No.: 24A918
3500 psi (24 MPa, 241 bar) Maximum Working Pressure
PRESSURE RELIEF PROCEDURE
Follow this procedure any time you are instructed to
Relieve the Pressure; shut off the pump; clean or ser-
vice any part of the system; or install or clean dispens-
ing devices.
1.
Disconnect power.
2.
Disable air supply to pump by either:
•
Closing bleed-type air valve
OR
•
Disconnecting quick disconnect air coupler on
vent valve.
SKIN INJECTION HAZARD
High-pressure fluid from gun or dispense valve, hose
leaks, or ruptured components will pierce skin. This may
look like just a cut, but it is a serious injury that can
result in amputation. Get immediate surgical treat-
ment.
•
Do not point gun or dispense valve at anyone or at
any part of the body.
•
Do not put your hand over the dispense outlet.
•
Do not stop or deflect leaks with your hand, body,
glove, or rag.
•
Follow Pressure Relief Procedure, when you stop
dispensing and before cleaning, checking, or servic-
ing equipment.
Important Safety Instructions
Read all warnings and instructions in this manual. See
your Automatic Lubrication System Manual for com-
plete Warnings, Installation, Operation and Trouble-
shooting instructions. Save all instructions.
1/8” npt
1/4” npt
ti13690
1/2” npt
9.5”
240.5 mm
2.75”
69.8 mm
3.75”
95.2 mm
2-27/32” (72.2 mm)
2-3/16” (55.6 mm)
EN