Troubleshooting
14
3A5056B
Troubleshooting
The status lights (see F
. 8) brighten and dim based on the output voltage of the appropriate channel.
If the light becomes dim or turns off when the field apparatus is connected, it may be drawing too much power for cor-
rect operation, or the device or cable may be shorted. Determine the fault and replace or repair parts as necessary.
The following tests can be used to validate the operation of the barrier:
Parts
* Part of G-Barrier Power Connector Kit 25E511
Parameter
Procedure
Valid Range
Input Voltage
Check with meter
12 VDC to 24 VDC
Output Voltage with no load
Check with meter
15 VDC
Output Voltage with load
Check with meter
Compare to current from graph. See
,
page 15.
Output Current with load
Check with meter
Compare to voltage from graph. See
page 15.
Part
Description
Qty
26A507
Circuit, IS power barrier
1
116343
Ground screw
1
19A612*
Power input connector, six position
3
17T870*
Power input connector, two position
1