Installation
03762
Fig. 2
KEY
A Vent Plug
B Bung Adapter
C Air Line Lubricator
D Bleed-type Master Air Valve
E Air Line Filter
F
Grounded Air Hose
G Fluid Drain Valve
H Fluid Outlet
J
Pin Fitting
K Air Control Valve
(All Models except 226–951)
L
Air Line Coupler
M Grounded Fluid Hose
CC Air Regulator Kit
(Model 226–951 only)
E
A
D
F
K
J L
H
G
M
C
B
13 mm (0.5”)
Model 226–951 only
C
D
CC
E J L
Mounting the Pump
Always rigidly mount the pump to suit the type of in-
stallation planned. Graco mounting accessories are
shown in the
Accessories
section. With 200 liter (55
gallon) drum length pumps, screw the bung adapter
(B) tightly into the bung hole of the drum and adjust to
hold the pump 13 mm (0.5 in.) off the bottom of the
drum. Loosen the vent plug (A) to prevent formation of
a vacuum in the drum. Stubby pumps may be mounted
on a wall or on the side of a drum with a clamp. Drum
pumps can also be mounted to the side of a drum.
NOTE:
Refer to
Dimensions
on page 38 for pump
dimensions, and air inlet and fluid outlet sizes.
If low level cut-off valve 210–865 is being used, install
a drum length pump (except Model 226–951) in the
container with the valve 210–865 resting on the con-
tainer bottom. This accessory valve will not fit pumps
with a telescoping suction tube, such as Model
226–951.
CAUTION
If low level cut-off valve 210–865 is used, install it
with a strap wrench to avoid damaging the valve.
Do not use the legs of the valve to tighten it into
the pump.