17
309224
Displacement Pump Service
Reconnecting the Displacement Pump
NOTE:
Before connecting the displacement pump to
the motor, check that a new copper gasket (39) is
inserted in the outlet housing (18).
1.
Place the displacement pump in a vise, with the
jaws on the pump cylinder (101). Position the air
motor (1) so the displacement rod (18) engages
the threads of the connecting rod (102). Using a
wrench on the nut (109), screw the connecting rod
into the displacement rod until the pin holes align.
See Fig. 8.
2.
Install the pin (112*) in the hole to secure the two
rods (17 and 102) together. Make sure the pin is
flush or below the surface of the rod (17). Screw
the motor (1) onto the cylinder (101) by hand. See
Fig. 7.
3.
Use a pipe wrench on the lower part of the outlet
housing (18) to securely tighten the motor (1) to
the cylinder (101). See Fig. 6.
4.
Apply thread sealant (113500*) and screw the
intake cylinder (110) onto the pump cylinder (101).
See Fig. 5.
5.
Remove the pump from the vise. Reinstall the
mounting plate (44) and secure with the retaining
ring (43).
6.
Mount the pump. Reconnect the air and fluid
hoses and return the pump to service.
2
Check that a new gasket (39) is
inserted in the outlet housing (18)
before connecting the motor to
the displacement pump.
Fig. 8
8765C
109
102 17
1
101
18
2