Installation
332453A
5
9.
Install a collar on the mast shaft for both chemical
rams.
10. Connect the cable end labeled “J1BA” to the base
sensor.
11. Connect the cable end labeled “J1BB” to the cata-
lyst sensor.
12. Route and secure access cable so it will not be
damaged during normal machine operation.
13. Turn the power on at the electrical enclosure.
14. Slide the collar so it is at the level of the sensor.
15. Adjust the sensor until it senses the collar. A light
will aluminate on the sensor to visually show it is
activated.
16. Tighten the sensor to its current position.
17. Adjust the collar on the shaft to the desired height
and tighten. The placement of the collar will deter-
mine when the machine will recognize an empty
drum.
18. Repeat steps 14 through 17 for the other chemical
sensor.
19. Navigate to the
Setup Screen 1
on the Display
Module (DM) and activate the low level sensor
option.