Setup
3A6165J
15
Setup
After placing the EFR in the desired area of operation:
NOTE:
Make sure the EFR is placed on a level surface.
See
on page 66 for space requirements.
1. Anchor the EFR to a fixed mounting location. See
on page 66.
2. Follow steps a through d to install pumps ordered
separately for EFR systems configured without
pumps. If the EFR is already configured with pumps,
proceed to step 3.
a. Adjust the electric driver position to the correct
ratio of the pumps selected. See
and
b. Install inlet fittings (provided with the EFR) onto
the A and B pumps purchased separately. See
c. Install the pumps onto the EFR. See
page 36. The B pump (larger volume) should be
located on the side of the driver electrical con
-
nections. Use spring clamps (106) (provided
with pumps) to couple the pump to yoke adapt
-
ers (216).
d. Install adapters (107) into the pump outlets,
then install outlet manifold assemblies (108,
109) and drain tubes (112).
3. If applicable, assemble and connect the fluid inlet
regulators to the EFR fluid inlets (J). See
4. Connect the supply systems.
a. Install feed pumps for component A (Red) and
b. Ensure the supply systems and, if applicable,
the inlet regulators are off or set to zero pres
-
sure before connecting.
NOTE:
Supply hoses from feed pumps should be 3/4 in.
(19 mm) ID minimum.
c. Assemble, connect and tighten the component
B (Blue) inlet hose to the B-pump inlet (J).
d. Assemble, connect and tighten the component
A (Red) inlet hose to the A-pump inlet (J).
inlet pressure
gauge
2000 psi max
inlet pressure
J