USB Data
64
333587B
USB Data
Download Procedure
NOTE:
If log files are not correctly saving to the USB
flash drive (for example, missing or empty log files),
save the desired data off of the USB flash drive and
reformat it before repeating the download procedure.
NOTE:
System configuration setting files and custom
language files can be modified if the files are in the
UPLOAD folder of the USB flash drive. See
, page
, page
, and
on page
.
1.
Insert the USB flash drive into the USB port.
2.
The Menu Bar and USB indicator lights indicate that
the USB is downloading files. Wait for USB activity
to complete.
3.
Remove the USB flash drive from the USB port.
4.
Re-insert the USB flash drive into the USB port of
computer.
5.
The USB flash drive window automatically opens. If
it does not, open the USB flash drive from within
Windows
®
Explorer.
6.
Open the GRACO folder.
7.
Open the system folder. If downloading data from
more than one system, there will be more than one
folder. Each folder is labeled with the corresponding
serial number of the ADM
NOTE:
The serial number is on back of the ADM.
8.
Open the DOWNLOAD folder.
9.
Open the DATAxxxx folder.
10. Open the DATAxxxx folder labeled with the highest
number. The highest number indicates the most
recent data download.
11. Open the log file. Log files open in Microsoft
®
Excel
by default as long as the program is installed.
However, they can also be opened in any text editor
or Microsoft
®
Word.
NOTE:
All USB logs are saved in Unicode (UFT-16)
format. If opening the log file in Microsoft Word, select
Unicode encoding.
USB Logs
NOTE:
The ADM can read/write to FAT (File Allocation
Table) storage devices. NTFS, used by 32 GB or greater
storage devices, is not supported.
During operation, the ADM stores system and
performance related information to memory in the form
of log files. The ADM maintains six log files:
•
Event Log
•
Pump X Log
•
Cycles Log
Follow the
, page
, to retrieve
log files.
Each time a USB flash drive is inserted into the ADM
USB port, a new folder named DATAxxxx is created. The
number at the end of the folder name increases each
time a USB flash drive is inserted and data is
downloaded or uploaded.
Event Log
The event log file name is 1-EVENT.CSV and is stored
in the DATAxxxx folder.
The event log maintains a record of the last 1,000
events and errors. Each event record contains:
•
Date of event code
•
Time of event code
•
Event code
•
Event Type
•
Event Description
Event codes include both error codes (alarms,
deviations, and advisories) and record only events.