Setup
3A8217A
27
Electrical Connections
Pressure Transducer
1. If using a Single iQ Ram Supply System, connect
the pressure transducer cable (PC) from dispense
valve (B) to Port 6 on the Electric Driver (AB). See
Electric Driver Communication Connections
for
Single Rams on page 16.
2. If using a Tandem iQ Ram Supply System:
a. Connect the Pressure Transducer Cable (PC)
from the Dispense Valve (B) to the Tandem
Block Valve Pressure Transducer Splitter. See
F
b. Connect one male end of the M12 5 pin
Pressure Transducer Splitter cable (ZZ) on the
Tandem Block (R) to Port 6 on the Electric
Driver (AB) on Ram 1. The second male end
goes to Port 6 on Ram 2. See
Electric Driver
Communication Connections
s on page 17.
F
IG
. 22
PC
Pressure Transducer Cable
Connection (XX).
Discrete Robot Cable
Connection (SS).
Dispense Valve solenoid
Cable Connection (YY).
M12 8 pin Discrete Robot
Splitter (RR).
M8 4 Pin Dispense Valve
Solenoid Splitter (TT) to
Splitter Attached to Port 4
on Electric Drive (AB) on
Ram 1 and Ram 2. Pin
M12 5 Pin Pressure
Transducer Splitter
Cable (ZZ) to Port 6
on Electric Drive
(AB) on Ram 1 and
Ram 2..
R
(NN)
Summary of Contents for E-flo iQ 26B543
Page 73: ...Wiring Diagrams 3A8217A 73 Wiring Diagrams...
Page 74: ...Wiring Diagrams 74 3A8217A...
Page 75: ...Wiring Diagrams 3A8217A 75...
Page 76: ...Wiring Diagrams 76 3A8217A...
Page 77: ...Wiring Diagrams 3A8217A 77...
Page 78: ...Wiring Diagrams 78 3A8217A...