Setup
Setup
Setup Screens
Screens
Screens
Use the Setup screens for pump
settings and accessory features. See
Screen Navigation and Editing, page 8
for
information on how to make selections and enter
data.
Inactive fields are grayed out on a screen.
NOTE:
NOTE:
NOTE: Before setting up profiles on Setup Screens
1–4, perform the initial setup on Setup Screens 5–22
to establish the configuration for your system and
affect the displayed data.
Setup
Setup
Setup Screen
Screen
Screen 1
1
1
Use this screen to set the operating mode for a
selected pump and profile.
Figure 11 Setup Screen 1
Setup
Setup
Setup Screen
Screen
Screen 1
1
1 Key
Key
Key
For systems with multiple pumps and
one display, select the pump (1 to 8)
from the menu.
NOTE: Three phase systems do not
support multiple pumps.
Select the profile (1 to 4) from the menu.
Select the operating mode
(force/pressure or flow) from the
menu.
• In force/pressure mode, the motor
adjusts the pump speed to maintain
the fluid pressure percentage set on
Setup Screen 2. If the flow limit is
reached before the target pressure,
the unit stops driving to the pressure
(if set as an alarm).
• In flow mode, the motor maintains
a constant speed to maintain the
target flow rate set on Setup Screen
3, regardless of the fluid pressure,
up to the pump’s maximum working
pressure.
If the system is equipped with a back
pressure regulator (BPR), set the target
air pressure to the BPR from 0 to 100
percent (approximately 1 to 100 psi).
Leave the field set to 000 for a system
with no BPR. This value represents the
percentage that is closed on the BPR. If
the value is greater than zero but there
is no BPR system, the L6CA error code
appears.
This softkey is disabled by default, and
only appears if the Profile
Profile
Profile Lock
Lock
Lock box is
checked on
.
Press to activate the profile that you just
edited.
12
3A2527H