Installation
308155U
5
Key:
A
Suction hose
B
Weep tube
C
Fluid outlet line (to gun)
D
Drain valve (required)
E
Ground wire
F
Hydraulic return line, minimum 3/4” I.D. (required)
G
Hydraulic outlet, 1/2 npt
H
Return line shut-off valve, minimum 3/4” (required)
J
Hydraulic inlet, 1/2 npt
K
Tee, 3/4 npt
L
*Supply line shut-off valve
M
*Pressure gauge
N
*Pressure reducing valve (required in systems over 1500
psi [10.2 MPa, 102 bar])
P
Accumulator
R
*Flow control valve (required in systems over 3 gpm [11
lpm])
S
Hydraulic supply line
T
Check valve
U
Variable volume pressure compensated pump
V
Hydraulic power supply
W Drain line, accumulator
X
Low-level cut-off valve
Y
Thermal Relief Kit (required)
* Included in Hydraulic Fluid Control Kit, 236864, which can be ordered separately.
Although the installation shown in F
IG
. 2 is only a guide for selecting and installing system components and accesso-
ries, some equipment is required, as noted in the key. For assistance in designing a system to suit your needs, con-
tact your Graco distributor.
Mount the pump to suit the type of installation planned.
F
IG
. 2: Typical Installation
A
B
C
D
E
F
G
H
J
K
L M
N
P
R
S
T
U
V
W
X
Y
Summary of Contents for Dyna-Star 224741