Technical Data
(Model 240946 Quiet King Pump and Model 237278 Reduced Icing Quiet King Pump)
To find Fluid Outlet Pressure
(psi/MPa/bar) at a specific fluid flow
(lpm/gpm) and operating air pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale to read fluid outlet
pressure.
To find Pump Air Consumption
(m /min or scfm) at a specific fluid
flow (lpm/gpm) and air pressure (psi/MPa/bar):
1. Locate desired flow along bottom of chart.
2. Read vertical line up to intersection with selected air consumption
curve (dashes). Follow left to scale to read air consumption.
A
0.6 MPa, 6.2 bar (90 psi) air pressure
B
0.5 MPa, 4.9 bar (70 psi) air pressure
C
0.3 MPa, 2.8 bar (40 psi) air pressure
Performance Charts
0
1000
2000
3000
4000
5000
0
1
2
3
4
Fluid Outlet Pressure
18
36
54
psi
MPa, bar
cycles per minute
gpm
liters/minute
3.8
7.6
11.4
FLUID PRESSURE
34, 345
28, 280
14, 140
A
B
C
0
50
100
150
200
0
1
2
3
4
Air Consumption
18
36
54
scfm
m
/
min
cycles per minute
gpm
liters/minute
3.8
7.6
11.4
AIR CONSUMPTION
A
B
C
5.60
2.80
Test Fluid: No. 10 Weight Oil
21, 210
7, 70
15.2
72
72
15.2
1.40
4.20
Summary of Contents for Dura-Flo 900