Operation
20
3A6941B
Operation
Note: Upper case letters used in the following
instructions refer to
Installation: Series Parallel System
and
Installation: Series Progressive System
diagrams
starting on page 9.
The unit must be securely mounted and grounded
before operation.
Priming the System
1.
After the tank (K) is completely filled, remove the
high pressure lubricant supply line (D) from the out-
let.
2.
Connect power to the pump (B).
3.
Start the pump (B) and run until all of the air has
been expelled and fluid flow is continuous (F
4.
Reconnect the high pressure lubricant supply line
(D) to the outlet.
Pump Operation Overview
Series Parallel System
1.
At the start of the cycle, the lubrication controller (F)
initiates a signal that closes the vent valve (L) and
starts the pump (B).
2.
The pump (B) builds pressure in the supply lines (D)
until all the injectors (E) actuate. Then the pressure
switch (T) sends a signal to the lubrication controller
(F) to end the cycle.
3.
The lubrication controller (F) terminates the signal
to the pump (B) and power to the vent valve (L).
4.
The vent valve (L) opens.
5.
Pressure is relieved in the supply lines (D), back into
the tank (K), and resets all of the injectors (E).
Series Progressive System
1.
At the start of the cycle, the lubrication controller (F)
initiates a signal to start the pump (B).
2.
The pump (B) supplies lubricant and pressure to the
metering devices (AD). When the metering devices
are active, they carry lubricant to the lube points.
3.
Continuous lubrication is provided during pump
operation.
4.
To control lubrication based upon number of cycles,
a cycle switch can be added to the metering
devices.
Shutdown
For normal shut down, disconnect power to the
lubricator controller (F) and to the pump.
F
IG
. 18
Summary of Contents for Compact Dyna-Star
Page 11: ...Installation 3A6941B 11 Typical Wiring Series Parallel Systems FIG 6...
Page 29: ...Maintenance 3A6941B 29 32 Remove the check valve and o ring 37 FIG 44 FIG 44 37...
Page 42: ...Parts 42 3A6941B 43 42 41 52 55 56 57 54 47 48 49 50 51 53...
Page 48: ...Mounting Dimensions Stand Alone Pump 48 3A6941B Mounting Dimensions Stand Alone Pump...
Page 49: ...Notes 3A6941B 49 Notes...