![Graco Check-Mate 450 Manual Download Page 7](http://html1.mh-extra.com/html/graco/check-mate-450/check-mate-450_manual_2253457007.webp)
308017
7
Installation
Fluid Line Accessories
Install the following accessories in the positions shown
in Fig. 1, using adapters as necessary:
D
Install a fluid drain valve (L) in a tee near the
pump fluid outlet. The drain valve is required in your
system to relieve fluid pressure in the displacement
pump, hose and gun/valve (see the WARNING on
page 6). Install with the drain valve pointing down,
but so the handle points up when the valve is open.
D
A fluid regulator (M) controls fluid pressure to the
gun/valve, and dampens pressure surges.
D
A gun or dispense valve (N) dispenses the fluid.
The gun shown in Fig. 1 is a high pressure dispens-
ing gun for highly viscous fluids.
D
A gun/valve swivel (P) allows freer gun/valve
movement.
Air and Fluid Hoses
Be sure all air hoses (S) and fluid hoses (R) are prop-
erly sized and pressure-rated for your system. Use
only electrically conductive hoses. Fluid hoses must
have spring guards on both ends.
05683
Fig. 1
KEY
A
Pump
B
19 Liter (5 Gallon) Air-Powered Ram
C
Wiper Plate
D
Air Manifold
E
Pump Runaway Valve (location shown)
F
Air Line Lubricator (location shown)
G
Pump Bleed-Type Air Valve
(required, for pump)
H
Pump Air Regulator
J
Air Line Filter
K
Bleed-Type Air Valve (for accessories)
L
Fluid Drain Valve (required)
M
Fluid Pressure Regulator
N
Airless Spray Gun or Dispensing Valve
P
Gun/Valve Swivel
Q
Ram Air Pressure Relief Valve
R
Electrically Conductive Fluid Supply Hose
S
Electrically Conductive Air Supply Hose
T
Ram Air Regulator
U
Ram Director Valve
V
Red-Handled Main Air Bleed Valve
W Air LIne Drain Valve
Y
Ground Wire (required, see page 8 for
installation instructions)
A
B
D
E
F
G
J
K
Y
R
T
L
N
P
S
M
C
W
H
S
V
Q
U
Summary of Contents for Check-Mate 450