background image

Summary of Contents for Airgard 224-040

Page 1: ...4 bar kXlMUMAIR INLET PRESSURE w Model 224 040 Series A TABLE OF CONTENTS Warnings 2 Installation 2 3 Troubleshooting 5 Operation 4 Service 6 Parts Drawingand List 7 Dimensional Drawing Back Cover Te...

Page 2: ...Construction Standards Part 1926 should be consulted INSTALLATION Reference letters and numbers in the text refer to Figs 1 and 2 and the Parts Drawing on page 7 Install an air filter A to remove harm...

Page 3: ...for pump E Pump Runaway Valve F Air Manifold Air Regulator Q Runaway Valve Swivel supplied RECOMMENDEDADAPTERS 175 013 Nipple 314 npt 157 191 Reducer 314 npt x 112 npt 160427 Swivel Adapter 314 npt m...

Page 4: ...gulator F and the bleed type master air valve C See Fig 1 counterclockwise NOTE A faint hissingsound from the runaway valve is from thepoppet vent H during operation normal The valve vents a small amo...

Page 5: ...t valve 11 14 15 is stuck open Disassemble and clean poppet valve See page6 Increased air pressure has caused pump Readjust valve and test See page4 speedto increase Interrupted or exhausted fluid sup...

Page 6: ...and the parts require replacement 12 Clean all parts and inspect for damage Se sure to clean all air passages cavities and surfaces REASSEMBLY See the Parts Drawing on page 7 1 2 3 4 5 6 7 a 9 Place...

Page 7: ...e pan hd 1032 unf 2a 0 312 7 9 mm long O RING bun N O RING buna N O RING nitrile O RING buna N PIN dowel SCREW cao hex hd M6 x 1 20 mm lbnrj GASKET copper SPRING compression PUSHBUTTON GASKET POPPET v...

Page 8: ...defectivepatis Theequipmentwiil be returned tothe original purohasertransportatlon prepaid Ifinspection ofthe equipment 308s not disclose any defect inmaterial or workmanship repairs will be made at a...