Instructions

Fill Valve

Refill manifold for use with Graco Auto-Fill Shut Off Valve only. For professional use only. 

Part No.: 
77X542
132230

5000 psi (34.4 MPa, 344.7 bar) Maximum Working 
Pressure
Part No. 132230: 3000 psi (20.7 MPa, 206.8 bar)

Important Safety Instructions

Read all warnings and instructions in this 
manual and in Electric DynaStar and Auto-Fill 
Shut Off Valve Instruction manuals. Save all 
instructions. 

Summary of Contents for 77X542

Page 1: ...ssional use only Part No 77X542 132230 5000 psi 34 4 MPa 344 7 bar Maximum Working Pressure Part No 132230 3000 psi 20 7 MPa 206 8 bar Important Safety Instructions Read all warnings and instructions in this manual and in Electric DynaStar and Auto Fill Shut Off Valve Instruction manuals Save all instructions ...

Page 2: ...system component See Technical Specifications in all equipment manuals Use fluids and solvents that are compatible with equipment wetted parts See Technical Specifications in all equipment manuals Read fluid and solvent manufacturer s warnings For complete information about your material request MSDS from distributor or retailer Do not leave the work area while equipment is energized or under pres...

Page 3: ...Remote Filling Station Pump pneumatic J Supply Hose user supplied K Supply Hose user supplied L Drain Hose M Fill Stud N Operating Instructions Label P Fill Valve Outlet Q Fill Valve Vent Port R Filter recommended if grease environment is contaminated Supply hoses must be rated for a minimum 5000 psi 34 4 MPa 344 7 bar pressure See Operation page 5 for additional information A B C D E F G H J L K ...

Page 4: ... will be located on the bottom of the block 3 Use mounting dimensions provided on page 7 of this manual to drill 4 mounting holes in the installa tion surface 4 Secure Fill Valve A to installation surface using 4 1 4 inch bolts 5 Select a convenient location close to the valve to adhere the Operating Instructions label N included with your valve NOTE Clean the surface prior to installing the label...

Page 5: ...ut and hold the Pressure Relief Plunger R long enough to relieve line pressure between Fill Valve A and Auto Fill Shut Off Valve C and between Remote Filling Station Pump H and Fill Valve A 10 Verify that the Pressure Relief Plunger R is seated and returned to the original position NOTE The length of time it takes to vent varies depend ing on the system design and installation In some installation...

Page 6: ...l pressure is manually relieved To help prevent serious injury from pressurized fluid such as skin injection splashing fluid and moving parts follow the Pressure Relief Procedure when you stop dispensing and before cleaning checking or servicing the equipment FIG 4 Problem Cause Solution Refill pump slows down or stalls and no output at the fill valve Auto Fill Shut Off Valve has not reset Be sure...

Page 7: ...lief value 3000 psi 10 20 7 MPa 206 8 bar 10 Maximum fluid flow 2 gpm 7 57 lpm Outlet port size Model 77X542 132230 3 4 inch npt Vent port size Model 77X542 132230 3 8 inch npt Inlet ISO 7241 1 Series B standard hydraulic quick disconnect 1 4 inch coupling Wetted parts zinc plated steel parts seals Buna N Dimensions See Dimensions and Mounting below Weight 5 06 lbs 2 3 kgs WARNING This product can...

Page 8: ...um China Japan Korea GRACO INC AND SUBSIDIARIES P O BOX 1441 MINNEAPOLIS MN 55440 1441 USA Copyright 2014 Graco Inc All Graco manufacturing locations are registered to ISO 9001 www graco com November 2019 Dimensions and Mounting Graco Information For the latest information about Graco products visit www graco com For patent information see www graco com patents TO PLACE AN ORDER contact your Graco...