Repair
3A4802D
29
Debris in Media Path
1.
Perform Draining the Pot procedure (page 18) to
remove as much media and water as possible.
2.
Perform Pressure Relief Procedure, page 7.
3.
Disconnect the abrasive hose at the control box,
and disconnect the blast hose. Shine a flashlight in
through the blast outlet connection. Inspect the inte-
rior of the pinch hose and blast circuit outlet for
debris. If debris or packed-out media is found,
remove then reinstall the blast hose and abrasive
hose and resume blasting.
4.
Remove the pot funnel assembly to gain access to
the inside of the pot.
5.
If visible, remove large debris and proceed to step
11. If water and media still remain in the pot and no
debris is visible, proceed to step 6.
6.
Remove the abrasive hose from the control box and
pot at the cam-lock fittings. If media flows freely
from the pot, debris is stuck in the abrasive hose.
Clear the hose and reinstall.
7.
If media is still stuck in the pot, loosen the clamp to
remove the outlet manifold.
ti30748a
WLD
WLD
WLD