Motor Control Diagnostics
332257A
21
Motor Control Diagnostics
NOTE:
•
Keep a new transducer on hand to use for test.
•
No display does not mean the sprayer is not pres-
surized. Before repair, perform
Pressure Relief
Procedure
, page 8.
1.
For sprayers with digital display, see Digital Display
Messages.
2.
Remove screws (12) and cover (50).
3.
Turn ON/OFF switch ON.
4.
Observe LED operation and reference following
table:
NOTICE
Do not allow sprayer to develop fluid pressure without
transducer installed. Leave drain valve open if test
transducer is used.
DISPLAY
LED
BLINKS
SPRAYER OPERATION
INDICATES
WHAT TO DO
No Display
Never
blinks
Sprayer stops. Power is not
applied. Sprayer must be
pressurized.
Loss of power.
Check power source. Relieve pres-
sure before repair or disassembly.
psi/bar/MPa
Once
Sprayer is pressurized.
Power is applied. (Pressure
varies with tip size and pres-
sure control setting.)
Normal operation
Do nothing
E=02
Two times
repeatedly
Sprayer may continue to run.
Power is applied.
Run away pressure.
Pressure greater than
4500 psi (310 bar, 31
MPa) or damaged pres-
sure transducer
Replace motor control board or pres-
sure transducer
E=03
Three times
repeatedly
Sprayer shuts down and LED
continues to blink three times
repeatedly
Pressure transducer is
faulty or missing
Check transducer connection. Open
drain valve. Substitute new transducer
for transducer in sprayer. If sprayer
runs, replace transducer
E=05
Five times
repeatedly
Sprayer does not start or
stops and LED continues to
blink five times repeatedly.
Power is applied.
Motor fault
Check for locked rotor, shorted wiring
or disconnected motor. Repair or
replace failed parts.
E=06
Six times
repeatedly
Sprayer stops and LED
blinks six times repeatedly.
Power is applied.
Motor is too hot or there
is a fault in motor ther-
mal device
Allow sprayer to cool. If sprayer runs
correctly when cool, check motor fan
function and air flow. Keep sprayer in
cool location. If sprayer does not run
when cool and continues to blink six
times, replace motor.
- - -
Power is applied.
Pressure less than 200
psi (14 bar, 1.4 MPa).
Increase pressure if desired. Drain
valve may be open.
E=10
Blinks 10
times
repeatedly
Sprayer does not start or
stops and LED continues to
blink 10 times repeatedly.
Power is applied.
High control board tem-
perature.
•
Make sure motor air intake in not
blocked.
•
Make sure control board is properly
connected to the back plate and
that conductive thermal paste is
used on the power components.