Troubleshooting
3A7031A
21
Troubleshooting
1.
Follow the
Pressure Relief Procedure
detailed in
the pump manual before working on the lubrication
system, pump, or lubrication lines.
Problem
Cause
Solution
Display or LED does not come on
Incorrect or loose wiring
Refer to
Input voltage is out of range
Confirm that the power source is
between 9 and 30 VDC.
Tripped external fuse
Confirm that none of the devices or
wiring connected to the controller
are causing a short circuit
connection. If necessary, replace
fuse.
Pump is not running during
lubrication event
Incorrect or loose wiring
Confirm current is being delivered to
the pump during a lubrication event.
Verify that your machine has been
wired correctly. Refer to
Controller output is incorrect
Confirm output voltage (Pump
) from controller during
lubrication event is correct (should
be similar to input voltage).
If controller output voltage is never
present, the device may need
replacement.
Measure at controller to ensure
there is not a wiring issue causing
the problem.
Reservoir runs out of grease quickly
and unexpectedly
TEST MODE is engaged
Turn off TEST MODE.
There is a leak
Check reservoir and lines for leaks.
Always in low level
Review ground difference between
the GLC X and the switch or sensor
Rewire if necessary.