background image

Graco Information 16Warnings 

2

311307E

Contents

Warnings   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2

Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4

System Plumbing   . . . . . . . . . . . . . . . . . . . . . . . .  4

Mounting Pump on Tank  . . . . . . . . . . . . . . . . . . .  5

Connection Hose   . . . . . . . . . . . . . . . . . . . . . . . .  5

Electrical Installation  . . . . . . . . . . . . . . . . . . . . . .  5

Priming  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6

Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7

Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Parts   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Technical Data   . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Performance Chart   . . . . . . . . . . . . . . . . . . . . . . 14

Notes  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Graco Standard Warranty  . . . . . . . . . . . . . . . . . . . 16

Graco Information  16

Warnings

The following general warnings are for the setup, use, grounding, maintenance, and repair of this 
equipment. Additional, more specific warnings may be found throughout the body of this manual 
where applicable. 

Symbols appearing in the body of the manual refer to these general warnings. 

When these symbols appear throughout the manual, refer back to these pages for a description 
of the specific hazard.

WARNING

FIRE AND EXPLOSION HAZARD 

When flammable fluids are present in the work area, such as gasoline and windshield 
wiper fluid, be aware that flammable fumes can ignite or explode. To help prevent fire 
and explosion:

Use equipment only in well ventilated area.

Eliminate all ignition sources, such as cigarettes and portable electric lamps. 

Keep work area free of debris, including rags and spilled or open containers of sol-
vent and gasoline.

Do not plug or unplug power cords or turn lights on or off when flammable fumes 
are present.

Ground all equipment in the work area.

Use only grounded hoses.

If there is static sparking or you feel a shock, 

stop operation immediately.

 Do not 

use equipment until you identify and correct the problem.

Keep a fire extinguisher in the work area.

ELECTRIC SHOCK HAZARD 

Improper grounding, setup, or usage of the system can cause electric shock.

Turn off and disconnect power at main switch before disconnecting any cables and 
before servicing equipment.

Connect only to grounded power source.

All electrical wiring must be done by a qualified electrician and comply with all local 
codes and regulations.

Summary of Contents for 260110

Page 1: ...pm 115 VAC 550 psi 3 85 MPa 38 5 bar Maximum Working Pressure Model 260113 4 0 gpm 16 lpm 115 VAC 470 psi 3 29 MPa 32 9 bar Maximum Working Pressure Model 260114 4 0 gpm 16 lpm 115 VAC 650 psi 4 55 MP...

Page 2: ...e and windshield wiper fluid be aware that flammable fumes can ignite or explode To help prevent fire and explosion Use equipment only in well ventilated area Eliminate all ignition sources such as ci...

Page 3: ...te the unit when fatigued or under the influence of drugs or alcohol Do not exceed the maximum working pressure or temperature rating of the lowest rated system component See Technical Data in all equ...

Page 4: ...ated pressure for the pump model used All plumb ing and hoses used in the installation should have a pressure rating compatible with the pump selected Flow and pressure switch settings If the system p...

Page 5: ...C models Models 260110 260111 260113 and 260114 use a 115 VAC single phase 60 Hz motor The electrical circuit supplying the motor must be on a circuit breaker and be rated to carry a minimum current g...

Page 6: ...tor will run continuously Ensure the small red wire remains on the front post Priming 1 Attach the connection hose to the outlet of the pump Insert the opposite end of the hose into the tank through t...

Page 7: ...itch ON Power switch is located on the back side of the motor 2 Place the outlet of the dispensing valve into the fill tube of the vehicle 3 Open the dispensing valve to the full open position until t...

Page 8: ...occur if filter or meter or automatic shut off nozzle is used If this occurs fill pump and meter with fluid through top of pump Motor does not run at proper speed Check electric connections Ensure su...

Page 9: ...re gears turn freely on shaft Clogged hose or nozzle Inspect and clean if required Operating pump more than 30 minutes continuous duty Limit operation to 30 minutes per hour Switch will not turn pump...

Page 10: ...Parts 10 311307E Parts Models 260110 260111 260113 and 260114 Model 260112 5 16 11 10 8 1 18 22 21 5 9 19 6 17 12 7 3 4 13 14 15 20 2...

Page 11: ...cap 5 16 18 x 1 in 4 22 SCREW cap 3 8 16 x 1 in 4 23 LABEL warning not shown Part no 15G901 1 Ref No Description Qty Kit Number Description Includes Items 260061 ADAPTER bung 12 260120 KIT fluid model...

Page 12: ...m 11 lpm Model 260113 4 0 gpm 16 lpm Model 260114 4 0 gpm 16 lpm Model 260112 3 0 gpm 11 lpm Inlet Size 3 4 in npt Outlet Size 1 2 NPT female Horsepower Model 260110 3 4 hp Model 260111 1 hp Model 260...

Page 13: ...s Length A Height B Width C Inches mm Inches mm Inches mm 260110 14 355 6 8 203 2 7 75 196 8 260111 14 75 374 6 9 228 6 8 5 215 9 260113 14 5 368 3 9 228 6 8 5 215 9 260114 17 431 8 9 228 6 9 75 247 6...

Page 14: ...Technical Data 14 311307E Performance Chart 5 54 4 02 3352 PSI BAR 0A 7 2 4 GPM LPM 0 24 5 23 0RESSURE SWITCH OPENS...

Page 15: ...Notes 311307E 15 Notes...

Page 16: ...of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY...