background image

Operation

311304H

9

Priming Pump

All pump models should prime within 5 seconds after 
pump is turned on up to a height of 36 in. (91 mm). 
Pumps installed at height up to 5 ft. (1.52 m) may have 
difficulty priming. Follow procedure below to initiate 
prime. Pumps installed at suction height above 5 ft. 
(1.52 m) will have difficulty in holding prime. It is recom-
mended that check valve (Graco part no. 260217) be 
added to the bottom of the suction tube to help maintain 
prime.

If prime in not achieved in 30 seconds after turning the 
pump on use the following procedure to initiate prime;

1. Remove 90° Union Swivel (15) from ¾” Inlet Nipple 

(14).

2. Pour fluid being pumped into pump outlet until com-

pletely filled. 

3. Re-assemble Union Swivel (15) back onto nipple 

(14). Turn pump on. The pump should gain prime in 
under 5 seconds.

4. If pump still does not gain prime check for any major 

leaks in the system. If no leaks are found then the 
pump is mechanically defective and should be 
reported to Graco Product Service for disposition.

It is important that the swivel end of the 90° union 
swivel (15) is assembled to the ¾” outlet nipple (14) 
for proper sealing (see fig. 6). Also, if the pump has 
difficulty priming it is easy to remove the swivel and 
pour fluid into the pump outlet cavity when assem-
bled this way.

If prime is lost

1. First make sure there are no fluid leaks from the 

pump outlet out to the fuel nozzle. Any leaks after 
the outlet will allow air to push the fluid column back 
to the tank and prime will be lost.

2. If no leaks are detected on the outlet side of the 

pump, remove the pump from the tank and inspect 
the suction tube and pump inlet for leaks. 

3. If the system is leak free and the suction height 

guidelines are followed the pumping system should 
not lose prime.

Operation

On/Off switch lever (8d) is located under nozzle holder. 
Remove nozzle before turning pump on.

1. Move switch lever (8d) on.

2. Insert nozzle into tank and actuate nozzle lever to 

dispense fuel.

3. Immediately after fueling turn switch lever (8d) off.

Maintenance

1. Clean inlet strainer (3b) after every 50 hours of 

operation.

2. To remove inlet strainer (3b), remove four screws 

(3c) and strainer cover (3a). Remove and clean 
strainer.

3. If strainer is excessively dirty, clean tank to protect 

pump and the equipment being fueled.

4. After cleaning strainer, replace strainer and cover. 

Make sure cover seal (3d/7e) is in place.

All guidelines and procedures are based on pump-
ing diesel fuel. If pumping gasoline priming may be 
more difficult due to the lift of gasoline dependent 
on Reid's vapor pressure of the gasoline and it's 
temperature. The lower the vapor pressure and 
temperature, the higher the possible lift. 

Before servicing, turn pump off and open the 
nozzle to relieve pressure.

CAUTION

Do not operate pump dry. Do not run pump for more 
than 5 minutes with nozzle closed. Do not operate 
pump for more than 30 minutes continuously in 1 hour.

Summary of Contents for 260000

Page 1: ...sted motor Models 260020 and 260021 10 gpm 38 lpm 24 VDC Models 260022 and 260023 12 gpm 45 lpm 230 VAC Models 260025 through 260028 12 gpm 45 lpm 115 VAC CSA C US listed motor 10 psi 0 07 MPa 0 7 bar...

Page 2: ...0078 manual unleaded 260013 260525 5 ft 1 52 m UL listed assembly 260078 manual unleaded 260014 260525 5 ft 1 52 m UL listed assembly 260078 manual unleaded 260015 260523 8 ft 2 44 m UL listed assembl...

Page 3: ...Models 311304H 3...

Page 4: ...t use equipment until you identify and correct the problem Keep a fire extinguisher in the work area ELECTRIC SHOCK HAZARD Improper grounding setup or usage of the system can cause electric shock Turn...

Page 5: ...MSDS forms from distributor or retailer Check equipment daily Repair or replace worn or damaged parts immediately with genuine Graco replacement parts only Do not alter or modify equipment Use equipme...

Page 6: ...st possible seal Allow cement to set for 5 min utes minimum before installing pump into tank CAUTION Do not use a curb pump automatic shut off nozzle with this pump Use of a curb pump automatic nozzle...

Page 7: ...ition pump as desired and tighten union nut 1k on bung adapter 9 Mounting Hose and Nozzle 1 Apply thread tape provided with pump to both ends of hose assembly Screw NPT end of 90 union swivel 15 to on...

Page 8: ...rical connection 13 Connect red wire with fuse holder inline to positive battery terminal Connect black wire to negative bat tery terminal Electrical Installation 115 VAC and 230 VAC 1 Ensure pump swi...

Page 9: ...m the pump outlet out to the fuel nozzle Any leaks after the outlet will allow air to push the fluid column back to the tank and prime will be lost 2 If no leaks are detected on the outlet side of the...

Page 10: ...trainer 3b clogged Remove and clean or replace Air leak in suction tube Inspect all joints in suction tube Make sure all joints in suction tube are sealed and that there are no cracks from over tighte...

Page 11: ...a binding Check to make sure gears turn freely on shaft Operating pump extended time with nozzle closed Do not exceed 5 minutes of operation with nozzle closed Clogged inlet strainer 3b Clean or repla...

Page 12: ...00 through 260017 260019 260024 260580 and 260581 12 VDC Models 260020 and 260021 24 VDC Models 260022 and 260023 230 VAC Models 260025 through 260028 115 VAC 1j 260450 260451 260452 260453 260457 260...

Page 13: ...21 KIT motor 115 VAC black includes items 2a 2i 253722 KIT motor 230 VAC black includes items 2a 2i 2a COVER electrical 1 2b HOUSING electrical 12 V 1 2c BOLT hex 1 4 20 x 3 4 in 10 2d NUT 10 32 2 2e...

Page 14: ...C and 24 VDC models only Ref No Description Qty 8 260433 KIT switch blue includes items 8a 8g 253718 KIT switch black includes items 8a 8g 8a COVER switch 1 8b BRACKET switch 1 8c CAM actuator switch...

Page 15: ...e 18 ft 5 5 m 14 AWG 12 VDC and 24 VDC models only Current draw 12 VDC models 12 5 amps 24 VDC models 7 amps 115 VAC models 2 amps 230 VAC models 1 amps Duty cycle 30 min hour Suction tube 1 in x 34 i...

Page 16: ...rkmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR...

Reviews: