Typical Installation
3A8571A
5
Typical Installation
The installations shown in F
. 3 are only guides for selecting and installing system components. Contact
your local Graco Distributor for assistance with planning a system to suit your needs.
NOTE: The output line fluid pressure should not exceed 200 psi (1.38 MPa, 13.8 bar) while pumping the fluid.
Exceeding this pressure can cause the motor to cycle on and off repeatedly.
The output pressure varies at the time of pump shut off. It is determined by many factors including: hose length,
type of fittings used, and the speed that the outlet valve is closed. If pressure sensitive devices are installed
downstream from the pump, an external pressure relief/bypass must be installed in order to vent excess pressure
back to the tank.
F
IG
. 1: Typical Installation - Option 1: Pump and Dispense Valve