Set Up
3A6711C
15
6.
Select the CALIBRATE option.
7.
Use the LEFT or RIGHT ARROWS to
/- and press the ENTER button.
8.
Note the current K-FACTOR is
displayed. In the example shown in F
9.
Calculate the new K-Factor using the
following equation:
Example:
Kcurrent = 169
Volume displayed on metered dispense valve
= 0.970 quart
Volume dispensed = 1 quart
Round to the nearest whole number: 163.9 =
164.
NOTE:
The unit of measurement for both
volumes must be the same in the above
equation.
10. Use the UP or DOWN ARROWS to
adjust the K-FACTOR to the K-FACTOR
(Knew) calculated in Step 9.
See Table 1, page 15 for recommended fluid
calibration factors.
NOTE:
Your calibration number may vary
slightly due to temperature or rate of flow.
Table 1
11. Press the ENTER button to complete the
calibration operation and save the new
calibration factor.
F
IG
. 19
F
IG
. 20
F
IG
. 21
Fluid
Calibration
Factor
Oil (10W30)
173
Gear Lube
173
ATF
173
Antifreeze
150
Windshield Washer
Solvent
150