Repair
3A4936E
9
Repair
Filter Element Replacement
The indicator (3) provides gradual warning of a dirty fil-
ter element (9). See Parts on page 10. The filter ele-
ment (9) needs to be cleaned or replaced when the
indicator (3) is 3/4 red.
1.
To reduce downtime, have a spare bowl (2), element
(9), and spring (7) on hand.
2.
Follow Pressure Relief Procedure, page 7.
3.
Open the fluid drain valve (B, see F
. 1), if used, or
remove the filter plug (8); have a container ready to
catch the drainage.
4.
Remove the bowl (2), element (9), and spring (7).
5.
Replace immediately with the spare bowl (2), ele-
ment (9), and spring (7) to keep the paint from dry-
ing on the housing (1) and other parts.
a.
Install the element (9) with the dome end up.
b.
Lubricate the threads of the bowl (2) with
grease before screwing it to the housing (1).
Tighten securely.
6.
Clean the bowl (2), element (9), and spring (7) you
removed with a compatible solvent before the paint
dries. Store until needed.
NOTE: Clean the element (9) with a small paint brush.
Blow out lodged particles with air, and inspect for dam-
age. Replace if ruptured, damaged, or too dirty to clean.
Filter O-Ring Replacement
The filter o-rings (5 and 6) seal the bowl (2) to the hous-
ing (1). See Parts on page 10. Replace the o-ring (5)
and o-ring backup (6) if material leaks around the bowl
(2).
1.
Follow Pressure Relief Procedure, page 7.
2.
Open the drain valve (B) and have a container ready
to catch the drainage. See F
. 1.
3.
Remove the bowl (2) and o-rings (5 and 6).
4.
Clean the parts in a compatible solvent. Be careful
not to damage the o-rings (5 and 6) or the sealing
surfaces of the bowl (2) and housing (1).
5.
Lubricate the parts with No. 2 grease.
6.
Replace the o-ring (5) and verify the o-ring backup
(6) is installed with the groove facing up.
Indicator Replacement
Replace the indicator assembly (3) if the indicator is not
working properly; for example, if it is always red or never
red.
Indicator O-Ring Replacement
The indicator o-rings (3a and 3b) seal the indicator
assembly (3) to the housing (1). See Parts on page 10.
Replace the o-rings (3a and 3b) if material leaks around
the indicator (3).
1.
Follow Pressure Relief Procedure, page 7.
2.
Open the drain valve (B) and have a container ready
to catch the drainage. See F
. 1.
3.
Remove the indicator (3) and o-rings (3a and 3b).
4.
Clean the parts in a compatible solvent. Be careful
not to damage the o-rings (3a and 3b) or the sealing
surfaces of the indicator (3) and housing (1).
5.
Lubricate the parts with No. 2 grease.
NOTICE
If the filter will not be used for awhile, thoroughly
clean all parts in solvent and blow them dry before
the paint dries and clogs the filter. To help prevent
damaging the parts, do not clean them with a wire
brush or sharp object.