Operation
4
3A8874A
Typical Setup
F
IG
. 1
Operation
See F
IG
. 1.
1. Set the outlet port cap (A) on the outlet port (F) of
the installed fluid cover.
NOTE:
Optional: Use a clamp to firmly hold the
outlet port cap (A) in place.
2. Connect the air hose (H) to the air hose adapter (C).
Securely tighten.
3. Firmly hold the outlet port cap (A) in place and open
the air supply valve (K).
4. Cover the inlet port (G) with the inlet port cap (D).
NOTE:
Optional: Use a clamp to firmly hold the inlet
port cap (D) in place.
5. Hold the caps (A, D) in place until the exposed
diaphragm retracts into position.
6. Install the second fluid cover. See your related
pump manual.
7. Close the air supply valve (K) and remove the
caps (A, D).
California Proposition 65
Key:
A
Outlet port cap
F
Outlet port
B
Air hose fitting
G
Inlet port
C
Air hose adapter
H
Air hose
D
Inlet port cap
J
Air regulator
E
Fluid cover
K
Air supply valve
A
B
C
D
E
F
G
H
K
J
CALIFORNIA RESIDENTS
WARNING:
Cancer and reproductive
harm – www.P65warnings.ca.gov.
Summary of Contents for 25F130