background image

Operation 

4

3A8874A

Typical Setup

F

IG

. 1

Operation

See F

IG

. 1.

1. Set the outlet port cap (A) on the outlet port (F) of 

the installed fluid cover.

NOTE: 

Optional: Use a clamp to firmly hold the 

outlet port cap (A) in place.

2. Connect the air hose (H) to the air hose adapter (C). 

Securely tighten.

3. Firmly hold the outlet port cap (A) in place and open 

the air supply valve (K).

4. Cover the inlet port (G) with the inlet port cap (D). 

NOTE: 

Optional: Use a clamp to firmly hold the inlet 

port cap (D) in place.

5. Hold the caps (A, D) in place until the exposed 

diaphragm retracts into position.

6. Install the second fluid cover. See your related 

pump manual.

7. Close the air supply valve (K) and remove the 

caps (A, D).

California Proposition 65

Key:
A

Outlet port cap

F

Outlet port

B

Air hose fitting

G

Inlet port

C

Air hose adapter

H

Air hose

D

Inlet port cap

J

Air regulator

E

Fluid cover

K

Air supply valve

A

B

C

D

E

F

G

H

K

J

CALIFORNIA RESIDENTS

 WARNING:

 Cancer and reproductive 

harm – www.P65warnings.ca.gov.

Summary of Contents for 25F130

Page 1: ...ofessional use only Kit 25F130 For models with 2 in ports Kit 25F131 For models with 2 5 in ports Kit 25F132 For models with 3 in ports Kit 25F133 For models with 3 5 in ports Important Safety Instructions Read all warnings and instructions in this manual and in your related equipment manual before using the equipment Save all instructions ...

Page 2: ... where applicable WARNING PRESSURIZED EQUIPMENT HAZARD Fluid from the equipment leaks or ruptured components can splash in the eyes or on skin and cause serious injury Follow the Pressure Relief Procedure when you stop dispensing and before cleaning checking or servicing equipment Tighten all fluid connections before operating the equipment Check hoses tubes and couplings daily Replace worn or dam...

Page 3: ...manual 2 Install diaphragms on both sides of the pump See your related pump manual 3 Install a fluid cover on one side of the pump See your related pump manual All kits include Ref Description Qty A Outlet port cap 1 B Air hose fitting 1 C Air hose adapter 1 D Inlet port cap 1 A C D B 1 1 Apply sanitary thread sealant 1 Equipment stays pressurized until pressure is manually relieved To help preven...

Page 4: ...ith the inlet port cap D NOTE Optional Use a clamp to firmly hold the inlet port cap D in place 5 Hold the caps A D in place until the exposed diaphragm retracts into position 6 Install the second fluid cover See your related pump manual 7 Close the air supply valve K and remove the caps A D California Proposition 65 Key A Outlet port cap F Outlet port B Air hose fitting G Inlet port C Air hose ad...

Page 5: ...Operation 3A8874A 5 ...

Page 6: ... material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warra...

Reviews: