Installation
3A6931A
9
Installation
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
Follow the Pressure Relief Procedure in the manual for
the air motor system you are converting. See
Related
Manuals
on page
for the air motor pump and supply
systems manuals.
Air to Electric Pump Conversion
Kits
The air to electric pump conversion kit is available in
three options depending on the pump lower size.
Disassemble the Air Motor Pump
NOTE:
Pumps can be mounted various ways in a
system. The following steps describe disassembling an
air motor pump that is mounted in a way that the pump
lower is easily accessible, such as on a wall mount or a
stand. If the pump is floor mounted or mounted in some
other way, you may need to remove the entire pump
from the system before disassembling it.
1.
Follow the
Pressure Relief Procedure
for the
Check-Mate or Dura-Flo air motor pump system you
are using. See
Related Manuals
2.
Remove the main air supply.
3.
See
Figure 1
and remove the pump coupling, pump
lower, and the three tie rods from the air motor
pump assembly. Refer to the Check-Mate Pump
Packages Instructions-Parts manual or the Dura-Flo
Pumps Instructions-Parts manual. See
Related
Manuals
on page
. Save these parts to be used
when installing the kit.
4.
Remove the air motor from the system.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the
Pressure Relief
Procedure
for the system you are using when you
stop spraying and before cleaning, checking, or ser-
vicing the equipment.
Kit Number
Pump Lower Size
25P277
CM100
25P278
CM200, CM250, DF115, DF145,
DF180, DF220, DF290
25P279
CM500, DF430
F
IG
. 1: Air Motor Pump
Pump Coupling
Tie Rods
Pump Lower
Summary of Contents for 25E202
Page 29: ...Installation 3A6931A 29 Notes...