background image

Warnings

Warnings

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The
exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific
risks. When these symbols appear in the body of this manual or on warning labels, refer back to these
Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout
the body of this manual where applicable.

DANGER

DANGER

DANGER

HIGH

HIGH

HIGH VOLTAGE

VOLTAGE

VOLTAGE ELECTRIC

ELECTRIC

ELECTRIC SHOCK

SHOCK

SHOCK HAZARD

HAZARD

HAZARD

This equipment uses high voltage power. Improper contact with high voltage equipment
will cause death or serious injury.

• Turn off and disconnect power at main switch before disconnecting any cables and

before servicing equipment.

• This equipment must be grounded. Connect only to grounded power source.
• All electrical wiring must be done by a qualified electrician and comply with all local

codes and regulations.

WARNING

WARNING

WARNING

FIRE

FIRE

FIRE AND

AND

AND EXPLOSION

EXPLOSION

EXPLOSION HAZARD

HAZARD

HAZARD

Flammable fumes, such as solvent and paint fumes, in work

work

work area

area

area can ignite or explode. Paint

or solvent flowing through the equipment can cause static sparking. To help prevent fire and
explosion:

• Use equipment only in well ventilated area.
• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and

plastic drop cloths (potential static arc).

• Ground all equipment in the work area. See Grounding

Grounding

Grounding instructions.

• Never spray or flush solvent at high pressure.
• Keep work area free of debris, including solvent, rags and gasoline.
• Do not plug or unplug power cords, or turn power or light switches on or off when flammable

fumes are present.

• Use only grounded hoses.
• Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless

they are antistatic or conductive.

• Stop

Stop

Stop operation

operation

operation immediately

immediately

immediately if static sparking occurs or you feel a shock, Do not use

equipment until you identify and correct the problem.

• Keep a working fire extinguisher in the work area.

3A4548G

5

All manuals and user guides at all-guides.com

Summary of Contents for 25C374

Page 1: ...in 55 55 55 gallon gallon gallon drums drums drums For For For professional professional professional use use use only only only Important Important Important Safety Safety Safety Instructions Instruc...

Page 2: ...nal Agitator Service 14 Parts 15 Models 25C483 and 25C484 15 Models 25C485 25C486 25C487 25C488 17 Models 25C374 25C451 25C480 25C481 19 Accessories 20 Dimensions 21 Models 25C483 and 25C484 21 Models...

Page 3: ...Agitator Approval Approval Approval 25C484 Back Gear Drive Only with Ground Wire Kit ATEX Listed Table Table Table 2 2 2 Models Models Models with with with UL UL UL Listed Listed Listed Explosion Exp...

Page 4: ...on Siphon Siphon Drum Drum Drum Cover Cover Cover Elevator Elevator Elevator and and and Cover Cover Cover Support Support Support Elevator Elevator Elevator Air Air Air Control Control Control Approv...

Page 5: ...ING WARNING FIRE FIRE FIRE AND AND AND EXPLOSION EXPLOSION EXPLOSION HAZARD HAZARD HAZARD Flammable fumes such as solvent and paint fumes in work work work area area area can ignite or explode Paint o...

Page 6: ...k or over bend hoses or use hoses to pull equipment Keep children and animals away from work area Comply with all applicable safety regulations MOVING MOVING MOVING PARTS PARTS PARTS HAZARD HAZARD HAZ...

Page 7: ...mage Do not lift the drum cover and agitator without proper assistance Do not walk or stand beneath a raised elevator With With With an an an Elevator Elevator Elevator Mount the drum cover as describ...

Page 8: ...e lined up 6 Push four cap screws 35 through the four holes in the blades and start the four lock nuts 36 onto the cap screws 7 Slide the loose blade assembly up the shaft and position it approximatel...

Page 9: ...hand hand tight is enough to hold the siphon tube in place NOTICE NOTICE NOTICE Barrel Barrel Barrel Heights Heights Heights Vary Vary Vary Loosen the retaining nut on the siphon tube retainer before...

Page 10: ...tor Equipment surfaces and fluid that is heated can become very hot during operation resulting in severe burns To avoid severe burns do not touch hot fluid or equipment Hazardous locations Install a h...

Page 11: ...e no leaks and that all fittings are tight NOTICE NOTICE NOTICE To avoid equipment damage be sure the motor rotation is set in a clockwise rotation when looking down on the motor fan blade and agitato...

Page 12: ...t is being supplied The agitator shaft speed can be calculated by using the formula below or determined by the graph below using the VFD frequency Example 1 AIB x C DIE F Example 2 40 hz I 60 hz x 172...

Page 13: ...e flush the inside of the agitator shaft 33 and clean the agitator blades 34 and the outside of the shaft 7 Reassemble the siphon tube by doing the reverse of steps 2 through 4 Servicing Servicing Ser...

Page 14: ...m nut 18 onto the agitator shaft by turning it clockwise and tighten it hand tight 3 Reposition the pinion gear assembly 10 15 in the lower housing thread the large gear 9 onto the agitator shaft and...

Page 15: ...rts Parts Parts Parts Models Models Models 25C483 25C483 25C483 and and and 25C484 25C484 25C484 Back Gear Back Gear Back Gear Drive Drive Drive 3A4548G 15 All manuals and user guides at all guides co...

Page 16: ...OCKET HEAD CAP M4 x 0 7 x 8 mm 3 18 190976 NUT 50 MM 1 Ref Ref Ref No No No Part Part Part No No No TEST TEST TEST Qty Qty Qty 19 113356 SCREW CAP SOCKET HEAD M6 x 1 x 60 mm 2 20 105489 PIN DOWEL 2 21...

Page 17: ...5 25C485 25C485 25C486 25C486 25C486 25C487 25C487 25C487 25C488 25C488 25C488 Agitator Agitator Agitator with with with or or or without without without Siphon Siphon Siphon 3A4548G 17 All manuals an...

Page 18: ...nits without Siphon 1 Ref Ref Ref No No No Part Part Part No No No Description Description Description Qty Qty Qty 32 117536 SCREW CAP SOCKET HEAD M8 x 1 25 x 25 mm 2 33 24D311 KIT SHAFT AGITATOR incl...

Page 19: ...ls 25C374 35C451 1 103 See 103a m COVER DRUM models 25C480 25C481 103a 190995 COVER BARE 1 103b 104029 STUD GROUNDING 1 103c 180755 WASHER TAB 1 103d 112903 WASHER SPRING LOCK M5 304 Stainless Steel 1...

Page 20: ...rt Part Part No No No Description Description Description 237524 Handles Kit 238250 Siphon Kit 238884 Return Tube Kit 17T255 Accessory Blade Kit Blades are 15 5 inch 39 4 cm diameter assembled 20 3A45...

Page 21: ...ive Model Model Model 25C483 25C483 25C483 Atex Atex Atex Listed Listed Listed Back Gear Back Gear Back Gear Drive Drive Drive Model Model Model 25C484 25C484 25C484 Reference Reference Reference Meas...

Page 22: ...ithout without Siphon Siphon Siphon Models Models Models 25C485 25C485 25C485 25C486 25C486 25C486 UL UL UL Listed Listed Listed Reference Reference Reference Measurement Measurement Measurement in cm...

Page 23: ...els 25C487 25C487 25C487 25C488 25C488 25C488 ATEX ATEX ATEX Listed Listed Listed Reference Reference Reference Measurement Measurement Measurement in cm Reference Reference Reference Measurement Meas...

Page 24: ...dels Models Models 25C374 25C374 25C374 25C451 25C451 25C451 UL UL UL Listed Listed Listed Reference Reference Reference Measurement Measurement Measurement in cm Reference Reference Reference Measure...

Page 25: ...1 25C481 Atex Atex Atex Listed Listed Listed Reference Reference Reference Measurement Measurement Measurement in cm Reference Reference Reference Measurement Measurement Measurement in cm A 14 14 35...

Page 26: ...Agitator Agitator Agitator RPM RPM RPM NOTE NOTE NOTE The power measured includes the VFD power usage ATEX ATEX ATEX Motor Motor Motor Power Power Power Usage Usage Usage Chart Chart Chart Power Powe...

Page 27: ...kg Agitator Blade Span 20 in 50 8 cm Agitator Blade Width 3 in 7 6 cm Wetted Parts 304 SST 304 304L SST Acetal AF Nylon PTFE Siphon Tube ID 3 4 in 19 mm Siphon Kit Threaded Outlet Size 1 npt Maximum A...

Page 28: ...TY AND AND AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AND AND FITNESS FITNESS F...