For complete warnings and operation instructions,
see the E-Flo DC Control Module Kit manual 3A2527.
Pump
Pump
Pump Control
Control
Control Module
Module
Module Nodes
Nodes
Nodes
Each station may have one pump that creates and
maintains fluid pressure in that station’s circulation
system. A Pump Control Module (PD) provides
the communication between each pump and the
Intelligent Paint Kitchen software.
Use each Pump Control Module’s keypad and display
to enter the node ID that was generated when the
station was configured.
Use the instructions in the E-Flo DC Control Module
Kit manual 3A2527 to access the Setup screens and
enter the correct node ID.
You must also use the Pump Control Module
software to set the control module to Network mode
and to set the baud rate.
NOTE:
NOTE:
NOTE: Entering the correct node ID into each
control module allows the Touchscreen Box (J) and
Supervisor Box (A) to communicate with each pump.
It does not set the speed or pressure of each pump.
Later in this setup process, you can create pump
profiles that determine pump operation under different
conditions. See
.
Set
Set
Set Up
Up
Up Tank
Tank
Tank Controls
Controls
Controls
For complete warnings and operation instructions,
see the Tank Control Module Kit manual 3A5991.
Tank
Tank
Tank Control
Control
Control Module
Module
Module Nodes
Nodes
Nodes
Every station that has a Secondary Tank (H) with
tank monitoring and an agitator must also have a
Tank Control Module (TD). This control module
looks identical to the Pump Control Module (PD),
but it contains different software. It provides the
communication between each Secondary Tank and
the Intelligent Paint Kitchen software.
Use each control module’s keypad and display to
enter the node ID that was generated when the
station was configured.
Use the instructions in the Tank Control Module Kit
manual 3A5991 to access the Setup screens and
enter the correct node ID.
When all node IDs have been entered into
the Variable Frequency Drives/Inverters
(B) and the Tank Control Modules, go
to
Turn on Node Communication, page 67
to
continue setting up the system.