Installation
16
313259B
7.
Slide Viscon HP heater (A) into slots on XM frame.
Tighten bolts to secure to frame.
8.
For heating hoppers or heating hoppers and
heated hose: install fitting (18) and elbow (17) in
the heater’s fluid inlet facing away from the XM
sprayer. Install elbow (7) in heater outlet facing the
back of the XM sprayer.
9.
For heating heated hose only: connect elbow fit-
ting (17) to heater fluid inlet facing the back of the
XM sprayer. Install elbow (7) in the heater’s fluid out-
let facing upward.
10. Wire Viscon HP heater (B) to your voltage supply.
Follow wiring procedure in the Viscon HP manual
309524.
11. If heating hoppers, remove bottom plug (P) from
hopper (C). Install elbows (32) and fittings (31).
Repeat for second hopper.
12. Remove side plug (P) used for fluid inlet.
13. Replace plug with bushing (6) and elbow fitting (7).
14. Cut tubing (4, 16, 29). See Tubing Lengths on
page 14.
NOTE:
Fitting nuts may need retightening as the system
reaches normal operating temperatures.
F
IG
. 9
F
IG
. 10
A
r_256273_313259_7
r_256273_313259_16a
18
17
7
r_256273_313259_17a
17
All wiring must be done by a qualified electrician. See
warnings, page 3.
P
P
7
6
32
C
r_256273_313259_8
31