Installation
4
3A4481F
Models 24Z714-24Z716 and
24Z719
NOTE:
•
Before installing the proximity switch cable, install the
proximity switch. See the Proximity Switch instruction
manual (provided with the proximity switch) for these
instructions.
•
Verify that the existing wiring configuration matches the
adapter.
•
NPN cable adapters require a 10-32 VDC power supply.
•
Cable pinouts are provided for trouble shooting purposes.
•
Cable Kits 24Z714, 24Z715 and 24Z716 allow the switch
to function as NPN but require a DC power source. Steps
2 - 4 provide instructions for reconfiguring the already
installed proximity switch cable.
•
For adapter cable 24Z719 only (F
Instructions for this cable kit begin with Step 5.
Instructions
1.
Disconnect power.
Steps 2 - 4 only apply to cable kits 24Z714, 24Z715 and
24Z716.
2.
Disconnect the green wire with a yellow stripe that is
currently grounded to the controller enclosure.
3.
Apply the blue shrink wrap (included in the kit) around the
wire so there is no green visible.
4.
Connect the shrink wrapped wire (now blue) to a 10-32
VDC power source.
Steps 5 - 7 apply to all kit models.
5.
Connect the adapter cable to the existing BH-mini con-
nection first.
6.
Connect the M12 connector to the proximity switch.
7.
Re-connect the main power. Test installation to verify the
proximity switch is operating correctly.
Adapter Cable - 24Z714 - 24Z716 and 24Z719
Model 24Z714
F
IG
. 5
F
IG
. 6
Connector 1
Connector 2
Polarity
Cable
Length
Straight 5 Pin
M12
NPN
12 in.