Appendix B - ADM Setup Screens Overview
54
3A2797ZAA
Shots Screen
This screen allows the user to edit shot definitions. The
contents of this screen change based on the flow units
selection. Shots are defined by flow rate and weight or
page 71 for information on how to use predefined
shots.
NOTE:
100 shot definitions are available across ten
pages.
To edit a shot definition:
1. Press
then use the arrow keys to navigate to
the desired value.
2. Type the new value then press
to accept the
new value.
3. If desired, press to quickly enter the same value
for the rate and time/volume/weight.
4. Repeat step 2 as required.
Due to variation in material properties, the ∆ column
gives the ability to adjust the shot time/volume/weight
for each defined shot.
NOTE:
If the ∆ column is used, it is recommended that
a minimum of 5 shots are dispensed, measured and
averaged for each dispense before entering a value for
the ∆ column.
Time Based Example:
A 75 cc/s shot is defined to dispense for 2 seconds.
1. Dispense 5 shots into 5 separate containers.
2. Measure the dispensed amount and record the
data.
3. Calculate the average of the 5 shots.
Example 1 = 146cc
Example 2 = 156cc
Shot
Example 1
Dispensed Volume
(cc)
Example 2
Dispensed Volume
(cc)
1
146.2
156.2
2
146.4
156.4
3
145.6
155.6
4
145.8
155.8
5
146.0
156.0