Troubleshooting
3A0590R
27
Troubleshooting
1.
2. Check all possible causes and solutions in the
troubleshooting chart before disassembling the
manifold.
Problem
Cause
Solution
Little or no resin output.
Fluid inlet is plugged.
Clean inlet; remove obstruction.
Fluid container is empty.
Refill.
Little or no hardener output.
Fluid inlet is plugged.
Clean inlet; remove obstruction.
Fluid container is empty.
Refill.
Hardener screen (18) is plugged.
Clean hardener screen. See
Mixed fluid will not flush out.
Fluid is hardened in static mixers or
whip hose.
Clean with compatible solvent. See
necessary.
Solvent supply container is empty.
Refill.
Solvent is not compatible with fluid.
Change to compatible solvent.
Hardener pressure higher than
normal.
Hardener is cold.
Correct heat problem.
Restrictor or screen plugging up.
Open restrictor or clean screen. See
Hardener pressure lower than
normal.
Resin is cold. Flow rate is low.
Correct heat problem.
Worn hardener restrictor.
Adjust restrictor. See
Restriction at the Mix Manifold
,
page 24.
Spray pattern developing tails.
Static mixer and/or whip hose
plugging up.
, page 26.
Clean spray gun and tip. See gun
manual.
Low pressure from proportioner.
Check air supply pressure. Check
inlet air gauges while spraying.
Cold material.
Increase heat.
Too much pressure drop.
Use larger hoses or more heat.
Not enough air supply. Gauge drops
while spraying.
Air hose is too small.
Compressor is too small.
Motor is icing.
Use De-Ice Bleed Air on motor. Dry
or cool air before use.
Wait for motor to thaw.
Dirty filter in pumps or spray gun.
Clean filters.